{"product_id":"ic697pwr711-ge-fanuc-series-90-30-power-supply-module","title":"IC697PWR711 GE Fanuc Series 90-30 Power Supply Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC697PWR711\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC697PWR711\u003c\/strong\u003e Power Supply Module, operates as a dedicated hardware component for power conversion and load distribution within Series 90-30 PLC platforms. The module accepts selectable input voltages of 120 VAC or 240 VAC through an external jumper setting to provide regulated direct current outputs and logic level sequencing across the system backplane.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIC697PWR711\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.64 kg (3.63 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSlide-in plug-in rack construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 Watts maximum input power at full load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 Watts maximum total output across all 3 rails\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Range, AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 to 132 VAC or 180 to 264 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput DC Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 to 150 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Frequency Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 0.93 (Power factor correction enabled with AC voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Rail 1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+5 VDC (4.90 to 5.25 VDC), 18 Amps maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Rail 2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+12 VDC (11.75 to 12.6 VDC), 2 Amps maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Rail 3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-12 VDC (-12.6 to -11.75 VDC), 1 Amp maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 Amps typical, 77 Amps maximum half-cycle peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHoldup Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21 milliseconds minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage Limit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+5 VDC Output: 5.7 to 6.7 Volts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Firmware Integration\u003c\/h3\u003e\n\u003cp\u003eThe IC697PWR711 mounts into the leftmost position of a GE IC697 rack or a VME integrator rack, establishing physical pathways via a 48-pin backplane connector. While the supply does not require backplane bus communication velocity licences to perform its power conversion tasks, it executes precise hardware logic level sequencing signals directly toward the backplane to coordinate power-up and shutdown phases with the host CPU. The architecture allows for flexible I\/O density scaling by supporting a 2-rack operation from a single supply unit, provided that the secondary chassis is joined via an approved 3-feet connecting cable and the net drawing current remains under 5.2 Amps.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the IC697PWR711 be replaced or serviced while the PLC backplane is energized?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. The IC697PWR711 requires full isolation of incoming field lines before extraction or installation. It features an integrated front-panel ON\/OFF switch to manually activate or deactivate secondary outputs, but primary field power must be isolated externally before disconnecting the module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the module contain onboard protection circuits against output faults?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The module features internal electronic short-circuit and overcurrent protection loops. The hardware limits current peaks to 26 Amps on the +5 VDC line, 4 Amps on the +12 VDC line, and 2 Amps on the -12 VDC line to safeguard attached backplane modules from electrical damage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Under what conditions must the technical ratings of this power supply be derated?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e For continuous operations in environments where high ambient temperatures and low line voltages occur simultaneously, the output specifications must be derated to ensure thermal profiles remain within safe tolerances.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Mounting:\u003c\/strong\u003e Slide the module into the leftmost slot position of the GE IC697 or VME rack structure, ensuring the 48-pin rear connector aligns true and seats fully.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage Jumper Validation:\u003c\/strong\u003e Prior to applying electrical power, verify the position of the external jumper to match the field supply (120 VAC or 240 VAC nominal) to prevent hardware overvoltage failures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecondary Rack Connection:\u003c\/strong\u003e When utilizing the 2-rack operational capability, use only the designated 3-feet connecting cable. Do not exceed 3 ft of physical separation as loop impedance may induce voltage degradation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBranch Fusing Requirements:\u003c\/strong\u003e Install an appropriately sized external branch circuit switch or fuse block upstream of the module to isolate line power during field servicing and maintenance routines.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43668033372250,"sku":"IC697PWR711","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC697PWR711.png?v=1784257798","url":"https:\/\/www.spareoil.com\/products\/ic697pwr711-ge-fanuc-series-90-30-power-supply-module","provider":"SpareOil Automation","version":"1.0","type":"link"}