{"product_id":"is210aedbh3adc-ge-hart-communication-module","title":"IS210AEDBH3ADC GE HART Communication Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE IS210AEDBH3ADC\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS210AEDBH3A\u003c\/strong\u003e Analog Input Module, operates as a dedicated hardware component for multi-channel field instrument data acquisition and digital protocol pass-through within GE PLC platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS210AEDBH3ADC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 to 65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC or 120 VAC Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e8 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.196%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Protocol\u003c\/td\u003e\n\u003ctd\u003e4-20 mA HART Loop Protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel-to-Channel Isolation\u003c\/td\u003e\n\u003ctd\u003eInput: 250 Vrms (or 150 Vrms) \/ Output: 500 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail Mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe IS210AEDBH3ADC digitizes 4-20 mA analog feedback loops using a high-resolution 16-bit analog-to-digital converter, achieving a measurement accuracy of +\/-0.196% across 8 input channels. Digital modulation signals superimposed via the 4-20 mA HART loop protocol pass directly through the hardware interface without interrupting primary variable sampling routines. To suppress common-mode ground loops and electrical interference from field instrumentation, the circuitry integrates robust input isolation rated at up to 250 Vrms and output isolation rated at 500 Vrms.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the input channel capacity and conversion parameters for the IS210AEDBH3ADC?\u003c\/p\u003e\n\u003cp\u003eA: The module accommodates 8 analog input channels operating with 16-bit conversion resolution and +\/-0.196% measurement accuracy.\u003c\/p\u003e\n\u003cp\u003eQ: What galvanic isolation limits apply to the input and output circuitry?\u003c\/p\u003e\n\u003cp\u003eA: The hardware incorporates input channel isolation rated at 250 Vrms (with specific documentation noting 150 Vrms) and output side isolation rated at 500 Vrms.\u003c\/p\u003e\n\u003cp\u003eQ: What primary power supply configurations can be connected to the module?\u003c\/p\u003e\n\u003cp\u003eA: The power input section supports either a 24 VDC or 120 VAC external power connection depending on cabinet distribution routing.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDe-energize all 24 VDC or 120 VAC power sources feeding the DIN rail distribution segment prior to module installation.\u003c\/li\u003e\n\u003cli\u003eWear a grounded electrostatic discharge (ESD) wrist strap before handling the printed circuit assembly.\u003c\/li\u003e\n\u003cli\u003eHook the top latch of the module onto the standard 35 mm DIN rail, then press firmly until the bottom mounting clip engages.\u003c\/li\u003e\n\u003cli\u003eRoute field 4-20 mA HART signal wiring through twisted-pair shielded cables to limit electromagnetic coupling.\u003c\/li\u003e\n\u003cli\u003eTerminate all cable shield drain wires at the main system earth ground bar rather than floating them inside the terminal housing.\u003c\/li\u003e\n\u003cli\u003eVerify channel wiring assignments and ensure field transmitter loop current power matches system supply ratings before applying input voltage.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43838353047642,"sku":"IS210AEDBH3ADC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IS210AEBIH2BE_3da1155e-936b-42be-bfd9-033d92aad12f.png?v=1786586931","url":"https:\/\/www.spareoil.com\/products\/is210aedbh3adc-ge-hart-communication-module","provider":"SpareOil Automation","version":"1.0","type":"link"}