{"product_id":"is220paich1b-ge-mark-vie-analog-input-output-module","title":"IS220PAICH1B GE Mark VIe Analog Input\/Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE IS220PAICH1B\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS220PAIC\u003c\/strong\u003e Analog Input\/Output Module, operates as a dedicated hardware component for analog field signal conversion and loop power distribution within Mark VIe control system platforms. The module interfaces with terminal blocks to digitize analog sensor inputs while delivering a nominal 22.8 VDC supply for field transmitter loops. Onboard signal processing manages diagnostic threshold monitoring, detecting channel anomalies such as high output current conditions.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS220PAICH1B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg (1.00 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e8.26 cm x 4.19 cm x 12.07 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 deg C (-40 to 158 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e22.8 VDC transmitter power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark VIe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input\/Output Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Acronym\u003c\/td\u003e\n\u003ctd\u003ePAIC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-Hazardous Cert\u003c\/td\u003e\n\u003ctd\u003eUL E207685\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX Zone 2 Cert\u003c\/td\u003e\n\u003ctd\u003eEN 60079-0:2018, EN 60079-7:2015, EN 60079-11:2012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm 66-67\u003c\/td\u003e\n\u003ctd\u003eIndividual output current too high relative to total current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe IS220PAICH1B mounts directly onto compatible terminal blocks, executing backplane bus communication velocity across dual Ethernet interfaces to maintain deterministic link synchronization with controller racks. Hardware filtering logic processes field analog inputs using percentage-of-span delta calculation methods, optimizing scan rate efficiency during high-density I\/O operations. Firmware flash compatibility across system revisions enables direct parameter configuration and dynamic firmware updates without interrupting adjacent channel transactions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What power output does the IS220PAICH1B provide for field transmitters?\u003c\/p\u003e\n\u003cp\u003eA: The module supplies an onboard 22.8 VDC power output designed to energize connected loop-powered analog transmitters.\u003c\/p\u003e\n\u003cp\u003eQ: What triggers PAIC Alarm 66-67 on this module?\u003c\/p\u003e\n\u003cp\u003eA: Alarm 66-67 is triggered when the detected individual output channel current rises above designated ratios relative to total output current load.\u003c\/p\u003e\n\u003cp\u003eQ: Is this module certified for installation in hazardous field locations?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module holds ATEX Zone 2, Group IIC compliance per EN 60079-0, EN 60079-7, and EN 60079-11 standards, in addition to standard UL E207685 certification.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Control:\u003c\/strong\u003e Wear an anti-static wrist strap connected to cabinet earth ground before handling the module to prevent electrostatic damage to internal processor components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Block Alignment:\u003c\/strong\u003e Align the rear connector carefully with the terminal block header pins before applying force to seat the module securely on the base hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Cable Termination:\u003c\/strong\u003e Connect transmitter shield wires directly to designated drain terminals on the I\/O terminal block to suppress electrical noise and ground loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConvection Clearance:\u003c\/strong\u003e Maintain vertical panel spacing to allow uninhibited ambient airflow through the module heat sink across the operational range of -40 to 70 deg C.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43856402415706,"sku":"IS220PAICH1B","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IS220PAICH1BG.png?v=1786956330","url":"https:\/\/www.spareoil.com\/products\/is220paich1b-ge-mark-vie-analog-input-output-module","provider":"SpareOil Automation","version":"1.0","type":"link"}