{"product_id":"is230sncih2a-ge-mark-vie-series-datasheet-technical-manual","title":"IS230SNCIH2A GE Mark VIe Series Datasheet \u0026 Technical Manual","description":"\u003ch2\u003eGE IS230SNCIH2A Mark VIe Discrete Input I\/O Module Pack\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE IS230SNCIH2A\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS230SNCIH2A\u003c\/strong\u003e Discrete Input I\/O Module Pack, serves as the primary \u003cstrong\u003eSNCI\u003c\/strong\u003e Discrete Input I\/O Cards utilized to execute dry contact signal capturing across GE Mark VIe and Mark VIeS platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIS230SNCIH2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e260 mm x 180 mm x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C (32 deg F to 140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBaseboard \/ IONet powered baseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDiscrete Input (Contact Input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Excitation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRedundancy Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSimplex (Single I\/O Pack configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual 100 Mbps Ethernet (IONet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptical isolation for field-to-logic protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Filter Delay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 ms to 100 ms (User configurable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSequence of Events (SOE)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupports 1 ms time-stamping resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIONet Deterministic Networks \u0026amp; Logic Processing\u003c\/h3\u003e\n\u003cp\u003eThe input pack mounts directly onto a compatible terminal board to execute high-density digitization of external contact closures. It generates a nominal 24 VDC excitation voltage to monitor field contacts, passing the raw state variations through optical isolation windows to decouple external surges from the internal microcomputer processing layers.\u003c\/p\u003e\n\u003cp\u003eData routing uses dual 100 Mbps Ethernet ports connected to the proprietary IONet deterministic networks. This architecture enables the module to transmit digitized input matrices directly to the master controller without introducing network jitter. An internal millisecond counter handles sequence-of-events (SOE) time-stamping tasks directly at the module boundary, ensuring state transitions are marked with 1 ms resolution prior to packet execution across the local control infrastructure.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the IS230SNCIH2A module support hot-swap extraction while the IONet backbone is active?\u003c\/strong\u003e \u003cstrong\u003eA: Yes.\u003c\/strong\u003e The mechanical design permits removal and insertion under power. However, because this is a Simplex architecture pack, pulling the unit immediately halts raw field signal scanning and forces all associated logic bits into their designated default fail states within the controller logic.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the hardware prevent mechanical switch contact bounce from triggering false input states?\u003c\/strong\u003e \u003cstrong\u003eA: The module relies on an onboard digital filtering matrix.\u003c\/strong\u003e Field inputs pass through hardware-level debouncing circuits where the processing delay is user-configurable from 4 ms to 100 ms, verifying state persistence before reporting the updated bit to the controller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum voltage isolation provided between the field-side 24 VDC contacts and the internal logic?\u003c\/strong\u003e \u003cstrong\u003eA: The hardware incorporates opto-isolators\u003c\/strong\u003e on each individual channel path. These optical gates construct a physical isolation barrier between the field terminal connections and the core microcomputer components, blocking common-mode electrical transients typical of industrial plant environments.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Board Alignment:\u003c\/strong\u003e Line up the back pins of the I\/O pack with the corresponding connectors on the terminal board tracking strip. Push the module frame firmly down until the mechanical locking screws are properly aligned, then tighten the retaining screws to the specified torque.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExcitation Shield Grounding:\u003c\/strong\u003e Wire all incoming dry contact signals using multi-conductor shielded cables. Ensure the cable shield terminates exclusively at the designated panel grounding bar to prevent stray electromagnetic interference from distorting the 24 VDC contact monitoring loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIONet Cable Configuration:\u003c\/strong\u003e Connect both 100 Mbps network lines to their assigned local IONet network switches using high-quality Cat 5e copper cabling. Confirm that both network links register independent traffic to verify data path redundancy is operational.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42870822994010,"sku":"IS230SNCIH2A","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/229._80ca9fb9-5e34-46dd-a39f-6c1eb15fb9ae.jpg?v=1772431320","url":"https:\/\/www.spareoil.com\/products\/is230sncih2a-ge-mark-vie-series-datasheet-technical-manual","provider":"SpareOil Automation","version":"1.0","type":"link"}