{"product_id":"kj2003x1-ba2-emerson-deltav-m-series-cpu","title":"KJ2003X1-BA2 | Emerson | DeltaV M-Series CPU","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmerson VE3005\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Assembly KJ2003X1-BA2 \/ 12P2093X112) serves as the central processing powerhouse for the DeltaV™ M-Series Distributed Control System (DCS). This \"Controller MD\" executes complex real-time control strategies, manages high-speed communication with I\/O subsystems, and facilitates seamless data exchange with the plant network. Engineered for high-availability environments, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVE3005\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports fully redundant configurations to eliminate single points of failure. We supply this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal hardware, ensuring your facility benefits from maximum processing integrity and long-term industrial stability.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePart Number Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVE3005\u003c\/strong\u003e: Primary DeltaV system model identifier for the MD Controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eKJ2003X1-BA2\u003c\/strong\u003e: Manufacturing assembly number for the M-Series Controller hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e12P2093X112\u003c\/strong\u003e: Internal Emerson hardware reference and revision code.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEmerson (USA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVE3005\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHardware Assembly\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKJ2003X1-BA2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDeltaV™ M-Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eController MD (CPU)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProcessor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-performance industrial-grade embedded CPU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOnboard Flash for strategies \u0026amp; RAM for data storage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRedundancy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports 1:1 Redundant Controller setups\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 °C to +60 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDeltaV Control Bus, Ethernet, Fieldbus support\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic Control Execution\u003c\/strong\u003e: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVE3005\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eruns the DeltaV control engine with high-speed precision. It executes PID loops, batch logic, and advanced control algorithms with consistent timing, ensuring stable process variables in volatile refinery and power generation environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBumpless Redundancy Transition\u003c\/strong\u003e: When paired in a redundant configuration, the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVE3005\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtinuously synchronizes its memory and state with the standby controller. In the event of a primary failure, the standby unit assumes control instantly without any \"bump\" to the process signals or field actuators.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified System Integration\u003c\/strong\u003e: The controller fits directly into the M-Series vertical carrier. This modular \"plug-in\" design allows engineers to expand system capacity or replace modules without complex re-wiring, significantly reducing downtime during hardware lifecycle management.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eComprehensive Self-Diagnostics\u003c\/strong\u003e: Integrated firmware performs continuous health checks on internal memory, processor integrity, and communication ports. The module reports fault codes directly to the DeltaV Explorer and diagnostic consoles, enabling proactive maintenance before a system-level event occurs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Communication Hub\u003c\/strong\u003e: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVE3005\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as the gateway between field I\/O and the operator workstations. It manages the flow of high-resolution data from HART, Foundation Fieldbus, and traditional analog\/digital modules, providing a unified view of the entire plant floor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the VE3005 require a specific power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVE3005\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edraws 24 VDC power through the DeltaV carrier backplane. We recommend utilizing a redundant bulk power supply (such as the VE5135) to ensure the controller remains energized during power source fluctuations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I upgrade an older M-Series controller to the VE3005 MD?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVE3005\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis compatible with standard M-Series carriers. However, you must verify that your DeltaV software version (v11.3.1 or higher is typically required for MD hardware) supports this specific controller model to ensure firmware compatibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the controller handle configuration storage?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module stores control strategies in non-volatile Flash memory. This ensures that the controller automatically reloads and executes its assigned strategies immediately upon a power cycle or system reboot without requiring manual intervention.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":43131522973786,"sku":"VE3005","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/345._65f9102b-ee3f-4c25-bae7-0fe8e8071d38.jpg?v=1774515073","url":"https:\/\/www.spareoil.com\/products\/kj2003x1-ba2-emerson-deltav-m-series-cpu","provider":"SpareOil Automation","version":"1.0","type":"link"}