{"product_id":"kj3002x1-bc1-12p0683x092-emerson-deltav-analog-output-module","title":"KJ3002X1-BC1 12P0683X092 Emerson DeltaV Analog Output Module","description":"\u003ch2\u003eEmerson KJ3002X1-BC1 DeltaV Series Analog Output Card\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson KJ3002X1-BC1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eKJ3002X1-BC1\u003c\/strong\u003e Analog Output Card, operates as a dedicated hardware component for driving field-side proportional devices within Emerson DeltaV Distributed Control System platforms. This hardware component interfaces 8 independent field-side loops directly with the core rack subsystem via internal backplane logic buses, converting digital control signals into continuous 4-20 mA current loops.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKJ3002X1-BC1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson (DeltaV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard DeltaV M-Series module footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e120 mA at 12 V DC (Local bus); 24 V DC field power required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8 Independent Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC (Active)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eplus\/minus 0.1 percent of span at 25 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Loading\u003c\/td\u003e\n\u003ctd\u003e0 to 600 ohm (Max load at 24 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Integrity\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation channel-to-channel and channel-to-system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; DCS Instrumentation Features\u003c\/h3\u003e\n\u003cp\u003eThe module integrates a dedicated 4-20 mA HART loop protocol layer enabling seamless pass-through communication between field instruments and the DeltaV engineering workstation. Internal measurement nodes feature individual channel-to-channel isolation parameters to mitigate ground loop currents and prevent common-mode voltage differentials from corrupting adjacent channels. For thermal safety and accuracy across varying installation conditions, electronic temperature sensors provide automated cold junction compensation (CJC) calculation routines when processing external thermocouple signals via matching terminal boards, ensuring deterministic A\/D converter scaling.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the KJ3002X1-BC1 support online hot-swap operations during continuous system execution?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports hot-swapping when inserted into a compliant DeltaV carrier interface; the hardware design mitigates transient signal disruption on adjacent slots during hot-insertion sequences.\u003c\/p\u003e\n\u003cp\u003eQ: How does the output circuit behave if communication with the local DeltaV controller is lost?\u003c\/p\u003e\n\u003cp\u003eA: The module relies on local hardware registers to execute configured fail-safe states, driving the 4-20 mA loop to either a predetermined low\/high value or holding the last valid control state.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePosition the KJ3002X1-BC1 module over the designated slot on the M-Series carrier, pressing firmly down until the mechanical latch engages into the lock tab.\u003c\/li\u003e\n\u003cli\u003eFasten the matching terminal block assembly to the module front connector, securing all retention screws to prevent contact resistance variation under vibration.\u003c\/li\u003e\n\u003cli\u003eRoute all 4-20 mA actuator loop cables through dedicated low-voltage wire ducts, maintaining physical separation from high-current AC power paths.\u003c\/li\u003e\n\u003cli\u003eTerminate the cable shields exclusively at the cabinet common instrumentation grounding bar to prevent the formation of ground loops.\u003c\/li\u003e\n\u003cli\u003eApply 24 VDC external field excitation power to the designated terminal pins and verify that the module power LED illuminates continuously post-initialization.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":42870829678682,"sku":"KJ3002X1-BC1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/138_d5a36a57-b5ef-46fb-9f08-4af60328b5c8.jpg?v=1772591241","url":"https:\/\/www.spareoil.com\/products\/kj3002x1-bc1-12p0683x092-emerson-deltav-analog-output-module","provider":"SpareOil Automation","version":"1.0","type":"link"}