{"product_id":"ks10-20-a-yokogawa-centum-vp-shielded-signal-cable-20m","title":"KS10-20*A Yokogawa CENTUM VP Shielded Signal Cable 20m","description":"\u003ch2\u003eYokogawa KS10-20*A Signal Cable\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa KS10-20*A\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eKS10\u003c\/strong\u003e Signal Cable, operates as a dedicated hardware component for stable mixed-signal transmission between field controllers, terminal boards, and subsystem I\/O modules within Yokogawa CENTUM VP and ProSafe-RS platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix \/ Style Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOption\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKS10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eShielded Multi-Core Signal Cable (50-50 Pins)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-20\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003eCable length 20 m class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e*\u003cstrong\u003eA\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003eStyle Code\u003c\/td\u003e\n\u003ctd\u003eStyle A (Dual-layer aluminum foil shield with drain wire, EMI attenuation up to 90 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKS10-20*A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.45 kg (Net) \/ 2.0 kg (Shipping)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eOuter diameter 8.5 mm, Cable length 20 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to 80 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive wiring component (N\/A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Structure\u003c\/td\u003e\n\u003ctd\u003e10 cores, tinned copper stranded (0.5 mm2 per conductor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e300 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation \u0026amp; Jacket\u003c\/td\u003e\n\u003ctd\u003eFlame-retardant PVC jacket (IEC 60332-1 compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding\u003c\/td\u003e\n\u003ctd\u003eAluminum foil with drain wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eYokogawa 50-pin standard signal connectors (KCN1 socket compatible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eYokogawa CENTUM VP, ProSafe-RS, ADM 2C, KS3 \/ KS10 systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe KS10-20*A cable passes high-density mixed analog and digital signals across 20-meter cabinet-to-cabinet interconnections without degradation. Full-length dual-layer aluminum foil shielding suppresses electromagnetic interference, maintaining channel-to-channel isolation limits across sensitive instrumentation channels. This noise attenuation preserves 4-20 mA HART loop protocol digital frequency-shift keying (FSK) signals during transmission through electrically noisy industrial control environments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the KS10-20*A cable require external terminal grounding during installation?\u003c\/p\u003e\n\u003cp\u003eA: The aluminum foil shield connects to an internal tinned drain wire. Field engineers must terminate this drain wire directly to a clean instrumentation earth ground at the cabinet entry terminal to optimize EMI attenuation and clear ground loop paths.\u003c\/p\u003e\n\u003cp\u003eQ: Can the 20-meter cable assembly be cut or modified in the field?\u003c\/p\u003e\n\u003cp\u003eA: Field modification is not recommended because factory-molded 50-pin connectors provide fixed-pin mapping and controlled impedance. Cutting the cable voids factory shielding integrity and pin-to-pin continuity standards.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eLay the KS10-20*A signal cable into designated low-voltage instrument raceways. Observe a minimum bend radius equal to at least eight times the 8.5 mm cable outer diameter to prevent structural strain on the internal stranded conductors and foil shield layers.\u003c\/p\u003e\n\u003cp\u003eMaintain strict separation between the KS10-20*A cable run and high-voltage AC power lines or variable frequency drive cables. Secure both 50-pin connector ends into their respective module or KCN1 terminal board headers using the integrated retention screws to prevent signal loss under continuous machine vibration.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43823333015642,"sku":"KS10-20*A","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/427_0d8ac69d-0707-4ff0-b482-b580bb9793ae.jpg?v=1786416639","url":"https:\/\/www.spareoil.com\/products\/ks10-20-a-yokogawa-centum-vp-shielded-signal-cable-20m","provider":"SpareOil Automation","version":"1.0","type":"link"}