{"product_id":"m2225-hima-safety-series-datasheet-technical-manual","title":"M2225 HIMA Safety Series Datasheet \u0026 Technical Manual","description":"\u003ch2\u003eHIMA M2225 Safety Series\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHIMA M2225\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eM2225\u003c\/strong\u003e Digital Output (Relay) Module, operates as a dedicated hardware component for safety-critical applications within HIMA safety platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eM2225\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHIMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e72 x 144 x 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8 relay outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003ePotential-free relay contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e2 A @ 24 VDC \/ 230 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Capacity\u003c\/td\u003e\n\u003ctd\u003e48 W (DC) \/ 500 VA (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;=10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eBuilt-in self-test, short-circuit and open-circuit detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 V RMS channel-to-ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Certification\u003c\/td\u003e\n\u003ctd\u003eSIL 3 (IEC 61508), PLe (EN ISO 13849-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Tolerance\u003c\/td\u003e\n\u003ctd\u003e5-95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, TUV approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHigh Reliability Safety Control (SIS)\u003c\/h3\u003e\n\u003cp\u003eThe module architecture incorporates SIL3 certification and PLe parameters to ensure structural code and signal execution viability. The circuit architecture uses internal triple modular redundancy (TMR) 2oo3 architecture pathways to continuously validate field command processing against localized hardware discrepancies. Complete galvanic isolation across potential-free relay interfaces minimizes circuit cross-talk, permitting direct fail-safe state execution at the physical layer when sensor or internal monitoring limits are breached.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What action does the M2225 module execute upon detecting an internal logic fault?\u003c\/p\u003e\n\u003cp\u003eA: The onboard diagnostic routines force all potential-free relay outputs immediately into their de-energized, fail-safe state to ensure process isolation.\u003c\/p\u003e\n\u003cp\u003eQ: Can the potential-free relay channels manage simultaneous AC and DC load variants?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the channels are isolated up to 1500 V RMS channel-to-ground, allowing individual loops to be configured for either 24 VDC or 230 VAC operation within standard contact rating metrics.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the unit securely on standard DIN-rail or directly onto a panel surface inside an enclosure that maintains a minimum rating of IP54. Field signal cables must be routed through distinct low-voltage terminal wireways, separated from high-capacity AC motor power distribution links. Field-side shield connections must terminate at a single point on the dedicated safety system master earth busbar. Ensure adequate ventilation margins around the IP20 chassis to prevent thermal accumulation when operating at maximum switching capacities.\u003c\/p\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":43484151087194,"sku":"M2225","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/288._c44af344-b4d1-4489-864f-7673dff5d687.jpg?v=1781228916","url":"https:\/\/www.spareoil.com\/products\/m2225-hima-safety-series-datasheet-technical-manual","provider":"SpareOil Automation","version":"1.0","type":"link"}