{"product_id":"mvi94-mcm-prosoft-technology-flex-i-o-modbus-network-interface","title":"ProSoft MVI94-MCM Modbus Communication Module for FLEX I\/O","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe MVI94-MCM is a high-performance Modbus communication interface module specifically engineered for the Rockwell Automation FLEX I\/O platform. This module acts as a bridge between FLEX I\/O processors and Modbus-compliant field devices, supporting both Master and Slave emulation modes. It is designed to handle complex data acquisition and control tasks in demanding industrial environments, including oil and gas, power distribution, and mining. By supporting up to 5000 registers, the MVI94-MCM enables seamless integration of field instrumentation into the control architecture, improving system response times and providing robust diagnostic capabilities.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupports Modbus RTU and ASCII protocols (Master or Slave).\u003c\/li\u003e\n\u003cli\u003eNative support for Enron Modbus, facilitating efficient floating-point data transactions for flow metering.\u003c\/li\u003e\n\u003cli\u003eConfigurable application port supporting RS-232, RS-422, or RS-485 physical layers.\u003c\/li\u003e\n\u003cli\u003eUser-definable memory mapping for flexible allocation of 5000 internal registers.\u003c\/li\u003e\n\u003cli\u003eHigh-speed data exchange via the FLEX I\/O backplane without requiring complex ladder logic messaging instructions.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThe MVI94-MCM is ideal for industrial automation applications requiring the integration of Modbus-based devices into a Rockwell Automation FLEX I\/O system, such as:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFlow metering and custody transfer systems.\u003c\/li\u003e\n\u003cli\u003eIntegration of variable frequency drives (VFDs) and smart sensors.\u003c\/li\u003e\n\u003cli\u003eRemote terminal unit (RTU) data concentration.\u003c\/li\u003e\n\u003cli\u003eProcess control in oil, gas, and utility infrastructure.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMVI94-MCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eProSoft Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eModbus Master\/Slave Network Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Compatibility\u003c\/td\u003e\n\u003ctd\u003eRockwell Automation FLEX I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e12 VDC or 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e340 mA at 12 VDC \/ 170 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegister Capacity\u003c\/td\u003e\n\u003ctd\u003e5000 Words\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 percent (Non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the FLEX I\/O backplane is powered down before installing or removing the module.\u003c\/li\u003e\n\u003cli\u003eMount the module securely onto the FLEX I\/O base unit, ensuring proper seating of the backplane connector.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for RS-422\/RS-485 connections to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of the communication cable shield at one end to prevent ground loops.\u003c\/li\u003e\n\u003cli\u003eVerify that the application port configuration (RS-232\/422\/485) matches the physical wiring before applying power.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate clearance around the module to ensure proper ventilation and cooling within the control cabinet.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eIs the MVI94-MCM compatible with all FLEX I\/O bases?\u003c\/h3\u003e\u003cp\u003eThe MVI94-MCM is designed to mount on standard FLEX I\/O terminal bases. Please verify your specific terminal base part number against the ProSoft installation manual to ensure mechanical and electrical compatibility.\u003c\/p\u003e\u003ch3\u003eDoes this module require complex programming?\u003c\/h3\u003e\u003cp\u003eNo, the module uses simple data movement within the processor's I\/O image, which simplifies integration and eliminates the need for complex messaging instructions in the PLC code.\u003c\/p\u003e","brand":"Prosoft","offers":[{"title":"Default Title","offer_id":43847450984538,"sku":"MVI94-MCM","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/wm_1_291d626f-6f6c-440d-8e3f-38b4f4572e87.jpg?v=1786727450","url":"https:\/\/www.spareoil.com\/products\/mvi94-mcm-prosoft-technology-flex-i-o-modbus-network-interface","provider":"SpareOil Automation","version":"1.0","type":"link"}