{"product_id":"new-emerson-5a26137g01-flame-retardant-signal-wire","title":"New Emerson 5A26137G01 Flame Retardant Signal Wire","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmerson Ovation 5A26137G01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a specialized interconnect solution for Distributed Control System (DCS) architectures. This high-performance shielded multi-core cable facilitates the seamless transmission of critical process signals and low-voltage power between Ovation controllers and I\/O modules. By utilizing high-purity copper conductors and robust shielding, this\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand-new\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecable maintains data transparency in high-interference power plant environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 5A26137G01 combines high-grade insulation with mechanical flexibility to meet rigorous industrial standards.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5A26137G01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConductor Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-Purity Annealed Copper\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConductor Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18 AWG\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCore Configuration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMulti-core (Typically 4-Pair Balanced)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShielding\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAluminum Foil + Tinned Copper Drain Wire\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInsulation \/ Jacket\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePVC \/ Flame-Retardant PVC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e300V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFlame Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUL VW-1, CSA FT4\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20°C to +90°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 × Cable Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUL, CSA, RoHS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElimination of EMI\/RFI Interference:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe integrated aluminum foil shield and dedicated drain wire suppress electromagnetic noise from nearby high-voltage equipment. This ensures that sensitive 4-20mA analog signals reach the controller without distortion or jitter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Chemical and Oil Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe flame-retardant PVC jacket resists degradation when exposed to common industrial lubricants and chemical vapors. This prevents jacket brittleness and short circuits in harsh refinery or chemical processing environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized for High-Density Routing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith a minimum bend radius of only six times its diameter, the 5A26137G01 navigates tight cable trays and cramped cabinet corners without compromising conductor integrity. This flexibility simplifies the wiring of complex I\/O racks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Thermal Stability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis cable maintains its electrical characteristics up to +90°C. The extended temperature rating prevents insulation melting or signal leakage during localized heat spikes common in power generation substations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 5A26137G01 be used for dynamic\/moving applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the cable offers high flexibility for installation, it is primarily designed for fixed or limited-movement industrial wiring. For continuous-motion robotics or cable carriers, we recommend verifying the specific cycle-life requirements of your application.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this cable include pre-terminated connectors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 5A26137G01 typically ships as a standard-length assembly (approx. 1.8m) or bulk spool depending on the specific G-code version. Always verify your required termination type—whether ferrule, spade, or proprietary Ovation connector—before final installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the shielding protect against ground loops?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe drain wire allows for a single-point grounding strategy. By grounding the shield at the cabinet end, the cable shunts induced noise to earth while preventing circulating currents that could introduce errors into analog loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the UL VW-1 and CSA FT4 ratings?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThese ratings certify that the cable jacket self-extinguishes during a fire. This prevents the cable from acting as a \"wick\" that carries flames between different control cabinets or plant areas, ensuring compliance with strict industrial safety codes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":43135993970778,"sku":"5A26137G01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/354._923bb974-d9d5-4ced-9b80-0de413963dba.jpg?v=1774574558","url":"https:\/\/www.spareoil.com\/products\/new-emerson-5a26137g01-flame-retardant-signal-wire","provider":"SpareOil Automation","version":"1.0","type":"link"}