{"product_id":"nfcp100-s00-yokogawa-stardom-fcn-controller-cpu-module","title":"NFCP100-S00 Yokogawa STARDOM FCN Controller CPU Module","description":"\u003ch2\u003eYokogawa NFCP100-S00 STARDOM FCN CPU Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa NFCP100-S00\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eNFCP100\u003c\/strong\u003e CPU Module, operates as a dedicated hardware component for executing IEC 61131-3 regulatory control loops and discrete sequence logic within Yokogawa STARDOM FCN autonomous controller platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNFCP100-S00 S3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA \/ Japan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.7 kg (1.70 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e76 mm x 127 mm x 127 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLow-power passive cooling (fanless architecture)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Protection\u003c\/td\u003e\n\u003ctd\u003eECC (Error-Correcting Code) RAM with power-cycle retention\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgramming Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61131-3 (LD, ST, FBD, SFC, IL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Protocols\u003c\/td\u003e\n\u003ctd\u003eDual Ethernet (supports redundancy), FTP, HTTP web server, SMTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eYokogawa STARDOM FCN Autonomous Controllers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and DCS Field Integration\u003c\/h3\u003e\n\u003cp\u003eThe NFCP100-S00 processing engine coordinates signal scanning cycles across local backplane I\/O buses to parse incoming process variables. When interfaced with field instrumentation, the CPU processes digitized values originating from 4-20 mA HART loop protocol transmitters, execute PID control algorithms, and feed updated target outputs back to field actuators. Internal ECC memory protection actively detects and corrects single-bit memory faults in real time, preventing memory corruption from interrupting continuous analog feedback loops or triggering unprogrammed system trips.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the NFCP100-S00 CPU module support fully redundant controller configurations?\u003c\/p\u003e\n\u003cp\u003eA: Yes, two NFCP100-S00 modules install side-by-side in a duplex base unit, providing seamless dual-redundant processing where the standby unit tracks memory state variables to assume control without interrupting output loops upon a primary CPU fault.\u003c\/p\u003e\n\u003cp\u003eQ: How does the fanless design affect installation heat dissipation requirements?\u003c\/p\u003e\n\u003cp\u003eA: The passive low-power architecture relies entirely on natural convection through top and bottom chassis vents. Installers must maintain standard vertical clearance above and below the module rack to preserve ambient airflow limits without requiring external fan assemblies.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the NFCP100-S00 CPU module directly into its designated base unit slot on the STARDOM FCN rack, ensuring the module latch mechanism snaps securely into place. Ground the base chassis to the main cabinet earth bus using a short, low-impedance copper conductor to mitigate high-frequency electrical noise.\u003c\/p\u003e\n\u003cp\u003eRoute both Ethernet communications cables through separate conduits to preserve physical path diversity when operating in dual-redundant network mode. Maintain a minimum distance of 200 mm between low-voltage communications wiring and high-current AC power cables inside the enclosure.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43823512027226,"sku":"NFCP100-S00 S3","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/688.1_ed0a7721-5b91-4610-a85e-1ec48f1bda11.jpg?v=1786417803","url":"https:\/\/www.spareoil.com\/products\/nfcp100-s00-yokogawa-stardom-fcn-controller-cpu-module","provider":"SpareOil Automation","version":"1.0","type":"link"}