{"product_id":"nfcp100-s00-yokogawa-style-s3-autonomous-controller-cpu","title":"NFCP100-S00 Yokogawa | Style S3 Autonomous Controller CPU","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa NFCP100-S00 (Style S3)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as the core intelligence for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSTARDOM FCN-100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAutonomous Controller series. This module effectively merges the agility of a PLC with the complex regulatory capabilities of a Distributed Control System (DCS). We provide this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, featuring advanced internal safety mechanisms and high-speed logic execution for mission-critical infrastructure.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown: NFCP100\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNFCP100\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCPU Module for STARDOM FCN-100 Field Control Node\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-S0\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStyle\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Hardware Style\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eType\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBasic Configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e(Style S3)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRevision\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent enhanced version with updated safety firmware and ECC memory\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Certification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 61508 SIL 3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eArchitecture\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInternal 2oo3 (Two-out-of-Three) Hardware Voting\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eECC (Error Correction Code) Protected RAM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eControl Network\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual-redundant Ethernet \/ Vnet\/IP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFieldbus Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFOUNDATION Fieldbus (FF-SIF), Modbus, HART\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eReal-time OS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProprietary Autonomous Controller Execution Environment\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 °C to +70 °C (Wide Range Support)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDNV-GL, CE, UL, CSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated SIL 3 Safety Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe NFCP100-S00 utilizes a unique\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2oo3 (Two-out-of-Three)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einternal voting mechanism within a single CPU module. This hardware-level diagnostic compares three separate execution paths to ensure data integrity. Unlike standard safety controllers that require dual-module hardware to reach high SIL levels, this single module reduces cabinet footprint while maintaining superior fail-safe performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMission-Critical Data Reliability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module incorporates\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eECC (Error Correction Code) memory\u003c\/strong\u003e, which identifies and repairs single-bit errors in real-time. This prevents the \"silent data corruption\" that often leads to unexpected processor reboots or system trips in high-vibration or electrically noisy environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAutonomous Edge Intelligence:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis controller excels in remote operations where network latency is a concern. It executes complex control strategies locally, logs historical data, and hosts its own web-based management interface. This ensures the plant remains safe even if communication with the central Human-Machine Interface (HMI) fails.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDirect FF-SIF Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe CPU natively supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFOUNDATION Fieldbus Safety Instrumented Functions\u003c\/strong\u003e. This allows engineers to build a complete, certified safety loop from the field transmitter through the NFCP100-S00 CPU to the final control element, simplifying compliance audits and system commissioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use the NFCP100-S00 to replace an older Style S1 or S2 module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The NFCP100-S00 Style S3 is fully backward compatible with the FCN-100 baseplate. It offers an immediate hardware upgrade with enhanced thermal management and more robust ECC memory handling compared to legacy revisions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this module suitable for offshore oil and gas applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Absolutely. With DNV-GL marine certification and a wide operating temperature range (-20 °C to +70 °C), the NFCP100-S00 thrives in corrosive and extreme environments. Its 2oo3 architecture prevents spurious trips, which is critical for remote offshore platforms where maintenance access is limited.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the module require a separate safety coprocessor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The safety logic and regulatory control logic run within the same NFCP100-S00 hardware environment. Its internal diagnostics meet SIL 3 requirements without necessitating secondary external hardware, drastically simplifying the safety instrumented system (SIS) design.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":42870906486874,"sku":"NFCP100-S00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/91_a72e79d2-c7df-4b6b-a851-b722cb124fed.jpg?v=1771053387","url":"https:\/\/www.spareoil.com\/products\/nfcp100-s00-yokogawa-style-s3-autonomous-controller-cpu","provider":"SpareOil Automation","version":"1.0","type":"link"}