{"product_id":"nfsb100-s50-yokogawa-128mbps-sb-bus-redundant-interface","title":"NFSB100-S50 Yokogawa 128Mbps SB Bus Redundant Interface","description":"\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa NFSB100-S50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-performance Network Field Switch and SB Bus Repeater Module specifically engineered for CENTUM VP and STARDOM Distributed Control Systems (DCS). This module facilitates high-speed, deterministic data exchange between controllers and remote I\/O units. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new and original\u003c\/strong\u003e, ensuring the highest level of network stability for mission-critical automation infrastructure.\u003c\/p\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe NFSB100-S50 serves as a dual-purpose communication hub, integrating Ethernet switching and SB Bus repeating into a single industrial-grade assembly. It handles data rates up to 128 Mbps on the SB Bus, providing the necessary bandwidth for high-density I\/O configurations. By managing redundant communication paths across both the SB Bus and Ethernet networks, the NFSB100-S50 eliminates single points of failure. Its robust aluminum housing and specialized circuitry protect the control network from electrical interference, making it a cornerstone for data integrity in large-scale process industries.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe NFSB100 series follows Yokogawa's specific coding for system integration:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNFSB100:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBase model for the Network Field Switch \/ SB Bus Repeater.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-S50:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesignates the standard type with specific hardware revision and interface capabilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSBT02:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOften associated with the terminal block or specific bus interface set used with this module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYokogawa Electric Corporation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNFSB100-S50\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSB Bus Speed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 128 Mbps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEthernet Speed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 Mbps \/ 1 Gbps (Configuration dependent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Protocols\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRedundant Ethernet, SB Bus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC Input\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.5 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e280 × 150 × 95 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAluminum and High-Impact Plastic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +60°C (32°F to 140°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.2 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic High-Speed Counting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 128 Mbps SB Bus speed ensures that the controller receives field data with minimal latency. This high-speed throughput allows the system to execute complex control loops without the bottlenecking found in standard fieldbus technologies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior EMI Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe aluminum housing acts as a Faraday cage, shielding internal electronics from high-frequency noise generated by nearby variable frequency drives (VFDs) and heavy switchgear.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Network Redundancy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe NFSB100-S50 supports duplexed bus setups. If one communication path experiences a physical break or signal loss, the module shifts data traffic to the secondary line instantly, preventing process interruptions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe robust metal construction efficiently dissipates heat generated during high-speed packet processing. This design ensures stable operation even when mounted in densely packed control cabinets where airflow is limited.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Scalability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module integrates easily into both CENTUM VP and STARDOM architectures. It supports a variety of network topologies, allowing for the expansion of I\/O nodes without redesigning the core communication backbone.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat cabling is required for the NFSB100-S50 Ethernet ports?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor 100 Mbps and 1 Gbps operation, use shielded CAT5e or CAT6 UTP cabling. To ensure maximum noise immunity in industrial environments, we recommend using high-quality industrial Ethernet cables with grounded connectors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the NFSB100-S50 require manual protocol configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module integrates directly into the Yokogawa engineering environment. The CENTUM VP or STARDOM software recognizes the module upon installation and handles the protocol synchronization, though specific IP addresses or bus IDs require assignment within the project database.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the NFSB100-S50 in a single (non-redundant) bus configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. While the module is optimized for redundant high-availability networks, it functions perfectly in single bus setups. This flexibility allows you to use the same hardware across different areas of a plant regardless of the local redundancy requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the NFSB100-S50 handle power fluctuations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module operates on a stable 24 VDC supply. It includes internal filtering to manage minor voltage ripples, but we recommend using a regulated industrial power supply to ensure long-term reliability and compliance with Yokogawa's operational standards.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43194901299290,"sku":"NFSB100-S50","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/196._4a0462d2-ece9-4a23-9a8a-f0a2d760d5b5.jpg?v=1775717709","url":"https:\/\/www.spareoil.com\/products\/nfsb100-s50-yokogawa-128mbps-sb-bus-redundant-interface","provider":"SpareOil Automation","version":"1.0","type":"link"}