{"product_id":"ntai06-symphony-harmony-16-ch-analog-input-termination","title":"NTAI06 Symphony Harmony 16-CH Analog Input Termination","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe ABB NTAI06 functions as a high-density Universal Analog Input Termination Unit (TU) specifically designed for Symphony Harmony and INFI 90 Distributed Control Systems (DCS). This unit bridges the gap between field-side sensors and system-level analog input modules, such as the IMASI23. It accommodates up to 16 universal channels, allowing for the simultaneous integration of current loops, thermocouples, and RTDs within a single footprint. We offer this unit as 100% Brand New and original equipment, providing the structural and electrical integrity required for power generation and heavy industrial process control.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNTAI06\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSymphony Harmony \/ INFI 90\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Channels (Universal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4-20 mA, ±10 V, 1-5 V, Thermocouples, mV, RTD\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±0.1% of Full Scale\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2000 V RMS (Input Isolation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommon Mode Rejection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120 dB @ 60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 °C to +70 °C (-40 °F to 158 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (WxHxD)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e218.44 mm × 236.22 mm × 96.52 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.43 kg (0.95 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe NTAI06 streamlines complex field wiring and enhances system reliability through a hardware-first design optimized for harsh industrial environments.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUniversal Signal Versatility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe NTAI06 eliminates the need for multiple specialized boards. By supporting 4-20mA current loops alongside millivolt and thermocouple signals on the same unit, it reduces spare parts inventory and simplifies cabinet design.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Signal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-performance components provide a 120 dB common-mode rejection ratio. This ensures that the NTAI06 filters out electromagnetic noise and interference common in heavy industrial settings, delivering clean data to the processor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtreme Environmental Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike standard commercial interfaces, the NTAI06 operates across a broad temperature range from -40 °C to +70 °C. This makes it suitable for unconditioned remote instrument enclosures or high-heat power plant environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2000 V RMS input isolation shields your expensive DCS control modules from field-side electrical surges and ground loops, preventing catastrophic system failure and minimizing downtime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhich ABB modules are compatible with the NTAI06?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe NTAI06 primarily interfaces with the IMASI23 Analog Input Module. It uses standard ABB ribbon cables to connect field signals directly to the input module in the Harmony rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the NTAI06 handle mixed signal types simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The universal nature of the 16 channels allows you to mix 4-20mA signals, thermocouple inputs, and RTDs on a single board, provided you configure the corresponding input module correctly in the software environment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the NTAI06 require external power for the 4-20mA loops?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe NTAI06 manages signal termination, but loop power requirements depend on whether you use the internal DCS power or an external source. The board provides the necessary terminal points to facilitate both configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a Brand New unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe guarantee that every ABB NTAI06 unit we supply is 100% Brand New and original. We do not sell refurbished or \"pulled\" hardware for safety-critical DCS applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":42903677960282,"sku":"NTAI06","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/483.1.jpg?v=1775806410","url":"https:\/\/www.spareoil.com\/products\/ntai06-symphony-harmony-16-ch-analog-input-termination","provider":"SpareOil Automation","version":"1.0","type":"link"}