{"product_id":"original-foxboro-p0914sq-fbm201-isolated-analog-module","title":"Original Foxboro P0914SQ FBM201 Isolated Analog Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFoxboro FBM201 (P0914SQ)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-precision analog input interface for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eI\/A Series\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDistributed Control System (DCS). This\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal module facilitates the integration of 8 isolated analog transmitter signals with the system's redundant Fieldbus. It accepts standard 0–20 mA or 4–20 mA DC signals, converting critical field data into accurate digital values for process monitoring. Designed for mission-critical industrial environments, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFBM201 (P0914SQ)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures superior signal integrity in petrochemical, power generation, and water treatment facilities where data accuracy and system uptime remain paramount.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFBM201 (P0914SQ)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Isolated Analog Input Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 20.4 mA DC (Standard 4–20 mA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMeasurement Accuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±0.05% of span\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eA\/D Resolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 to 16-bit (Configurable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Architecture\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGalvanic isolation withstands 600 V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRedundant Fieldbus Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOnboard Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 MB SDRAM, 32 MB Flash\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Input\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 V DC (Redundancy Supported)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to +60 °C (32 to 140 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.5 cm x 11 cm x 11.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.3 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Precision Signal Conversion:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFBM201 (P0914SQ)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edelivers an accuracy of ±0.05% of span. This high-resolution measurement capability allows the DCS to monitor subtle process fluctuations in critical loops, directly improving product quality and safety margins.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Galvanic Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndustrial field environments often suffer from ground loops and electrical surges. This module provides 600 V AC isolation between the field-side inputs and the internal logic, protecting the control processor and ensuring that noise on one channel does not corrupt data on another.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant Communication Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module utilizes a redundant Fieldbus interface to maintain constant data flow. If one communication path encounters a fault, the module automatically switches to the secondary path without interrupting the process scan.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Modular Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe slim 4.5 cm wide profile maximizes rack density. This compact footprint allows engineers to install more I\/O points in a smaller cabinet space, reducing total infrastructure costs and simplifying cable management.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Hardening:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOptimized for unconditioned industrial environments, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eP0914SQ\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithstands significant thermal stress. Its rugged architecture ensures long-term reliability in facilities with high humidity or fluctuating temperatures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the FBM201 handle 0-20mA and 4-20mA signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eP0914SQ\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports a full input range of 0 to 20.4 mA DC, making it compatible with both 0-20mA and 4-20mA industrial transmitters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the FBM201 (P0914SQ) hot-swappable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module supports installation and removal on a powered baseplate. When replacing a module, the system automatically downloads the configuration to the new unit, minimizing downtime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require external power for the transmitters?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the module provides isolation and signal processing, you must ensure the field loop is powered according to your specific Termination Assembly (TA) and transmitter wiring requirements (2-wire vs. 4-wire).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":43102907531354,"sku":"FBM201 P0914SQ","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/298._bd9de95a-a43b-40eb-940d-9fd921e4a47b.jpg?v=1774315490","url":"https:\/\/www.spareoil.com\/products\/original-foxboro-p0914sq-fbm201-isolated-analog-module","provider":"SpareOil Automation","version":"1.0","type":"link"}