{"product_id":"p0916fh-foxboro-analog-digital-input-module-new-original-stock","title":"P0916FH Foxboro Analog Digital Input Module | New \u0026 Original Stock","description":"\u003ch2\u003eFoxboro P0916FH FBM2xx Series\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-density analog and digital signal interface tasks in Foxboro I\/A Series distributed control systems, the \u003cstrong\u003eFoxboro P0916FH\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eP0916FH\u003c\/strong\u003e PLC Module, provides direct physical\/electrical execution. It serves as the physical connectivity link between field instruments and the system backplane, managing a maximum of 16 configurable input\/output channels. The subsystem incorporates a dedicated interface cable, designated as \u003cstrong\u003eP0916FH-C\u003c\/strong\u003e, which provides a 1-meter physical termination pathway between the active electronic module and the associated FBM2xx field termination assembly.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eP0916FH\u003c\/strong\u003e: Core active electronic module housing the processing circuitry, galvanic isolation barriers, and standard high-density backplane interface connectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eP0916FH-C\u003c\/strong\u003e: Dedicated Type 4 terminal cable assembly featuring a fixed length of 1 meter, deployed exclusively to interface the core P0916FH module to external FBM2xx termination blocks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eP0916FH \/ P0916FH-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eFoxboro (Invensys)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.0 kg (Module), 480 g (Pulse Assembly), 0.72 lbs (Cable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e40 x 30 x 20 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +125 deg C (Module), 0 to +60 deg C (Pulse Assembly)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC Nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 configurable channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Rate\u003c\/td\u003e\n\u003ctd\u003eUp to 10000 samples\/sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e2 A per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Input Range\u003c\/td\u003e\n\u003ctd\u003e0.1 Hz to 50 kHz (via FBM242 termination assembly)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage (Pulse)\u003c\/td\u003e\n\u003ctd\u003e-30 VDC to +30 VDC (NPN\/PNP, dry contacts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation per channel; opto-isolation to backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP65 or higher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocols\u003c\/td\u003e\n\u003ctd\u003eModbus RTU, Foxboro I\/A Series backplane protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; DCS Instrumentation Matrix\u003c\/h3\u003e\n\u003cp\u003eThe module operates with integrated channel-to-channel isolation to prevent ground loop currents from degrading analog measurement accuracy across the 16 signal paths. When processing low-level analog inputs or interfacing with remote instrumentation, the galvanic isolation barrier maintains signal integrity against high common-mode voltages common in industrial plant environments. Furthermore, the subsystem supports direct integration with specialized FBM242 termination blocks to execute cold junction compensation (CJC) during thermocouple-level temperature monitoring operations, maintaining digital precision through internal reference voltage balancing across the backplane bus.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the P0916FH-C cable assembly be hot-swapped while the active P0916FH module is powered?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. Disconnecting the P0916FH-C interface cable during active system operation breaks the electrical loop of all 16 channels simultaneously. This can induce inductive transients and cause the I\/A Series controller to instantly register a channel-fail fault. Power down the loop or place the associated control blocks into manual\/bypass mode before servicing the cable assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the mechanical limitation of the P0916FH-C interface cable route?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The P0916FH-C is a Type 4 terminal cable with a rigid 1-meter physical length restriction. It cannot be spliced, extended, or daisy-chained without introducing signal attenuation and degrading the high-speed 10000 samples\/sec acquisition performance.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure and Orientation\u003c\/strong\u003e: Mount the module inside an IP65 or higher rated industrial enclosure to comply with operating temperature tolerances (-40 to +125 deg C). Ensure vertical alignment on the mounting rack to optimize passive thermal dissipation across the stainless steel housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing and Bend Radius\u003c\/strong\u003e: Secure the P0916FH-C cable assembly using integrated strain reliefs. Maintain a minimum bend radius of 10 times the cable diameter to prevent internal conductor stress and shield degradation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding\u003c\/strong\u003e: Terminate all field instrument shields at the designated grounding bar on the FBM2xx termination block. Do not loop ground wires or establish multiple ground connections, as this creates ground loops that interfere with the galvanic isolation sub-circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Engagement\u003c\/strong\u003e: When wiring pulse inputs or analog loops to the termination assembly, strip insulation to the specified length and torque terminal screws to standard industrial ratings to prevent intermittent contact resistance.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":43468118949978,"sku":"P0916FH","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/433._4e5a5692-878e-4155-8539-4341ce188e49.jpg?v=1780966602","url":"https:\/\/www.spareoil.com\/products\/p0916fh-foxboro-analog-digital-input-module-new-original-stock","provider":"SpareOil Automation","version":"1.0","type":"link"}