{"product_id":"p0916rh-foxboro-i-a-series-fbm219-termination-assembly-module","title":"P0916RH Foxboro I\/A Series FBM219 Termination Assembly Module","description":"\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eFoxboro P0916RH FBM219 Termination Assembly Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for electrical termination and loop monitoring in Foxboro I\/A Series system architectures, the \u003cstrong\u003eFoxboro P0916RH\u003c\/strong\u003e (\u003cstrong\u003eFBM219\u003c\/strong\u003e Termination Assembly Module) provides direct physical\/electrical execution. This hardware interface maps field-side signal paths directly to host I\/O processors via channel-isolated wiring networks, eliminating signal degradation across high-density control loops.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eP0916RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFoxboro (Invensys \/ Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA \/ Mexico\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.75 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 mm x 45 mm x 115 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 W max at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFoxboro I\/A Series FBM219\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 Input Channels (Group Isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput On-State Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Off-State Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Current (Typical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.2 mA at 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Applied Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 VDC max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Load Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.25 A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Leakage Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.25 mA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoop Power Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCurrent limited to 2.5 mA per input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard DIN Rail \/ Cabinet Enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Isolation and Signal Integrity\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFoxboro P0916RH\u003c\/strong\u003e incorporates channel-to-channel and group galvanic isolation across all 24 Discrete Input Voltage Monitoring channels to prevent ground loops in high-noise DCS industrial environments. Ground potential differentials between field sensing devices and backplane processing electronics remain isolated, preserving signal clarity across continuous control loops. Integrated loop power protection limits fault current to 2.5 mA per input leg, maintaining systemic stability under field wire short-circuit events while keeping overall heat dissipation capped at 6 W max at 24 VDC.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the input impedance threshold required to trigger an On-State status on the P0916RH?\u003c\/p\u003e\n\u003cp\u003eA: The input circuit registers an On-State condition when the source resistance drops below 1 kOhm maximum at 15 VDC, drawing a typical current of 2.2 mA at 30 VDC.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle overcurrent conditions on loop power connections?\u003c\/p\u003e\n\u003cp\u003eA: Integrated current-limiting circuitry caps loop power output to 2.5 mA per input leg, protecting internal terminal trace pathways from short-circuit damage.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Orientation\u003c\/strong\u003e: Secure the module onto a 35 mm DIN rail within an IP54-rated cabinet. Ensure vertical spacing of at least 50 mm above and below the assembly for natural convection cooling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Terminals\u003c\/strong\u003e: Strip field wiring conductors to 6 mm. Torque screw-type terminals to 0.5 Nm (4.4 in-lb) maximum. Verify that field signal cables do not exceed the maximum source resistance limit of 1 kOhm for On-State operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Shielding \u0026amp; Grounding\u003c\/strong\u003e: Terminate overall cable shields at the dedicated cabinet ground bar using low-impedance grounding clamps. Do not connect field cable shields at both ends to prevent earth loop circulating currents.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":43917897728090,"sku":"P0916RH","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/451_04682061-db1c-488d-89f4-7d822d0d1304.jpg?v=1787797906","url":"https:\/\/www.spareoil.com\/products\/p0916rh-foxboro-i-a-series-fbm219-termination-assembly-module","provider":"SpareOil Automation","version":"1.0","type":"link"}