{"product_id":"p0926jma-foxboro-dcs-system-baseplate-datasheet","title":"P0926JMA Foxboro DCS System Baseplate Datasheet","description":"\u003ch2\u003eFoxboro P0926JMA I\/A Series Baseplate\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFoxboro P0926JMA\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eP0926JMA\u003c\/strong\u003e Baseplate, operates as a dedicated hardware component for physical module mounting and backplane power distribution within I\/A Series Distributed Control System platforms. The hardware establishes direct physical and electrical execution for structural power routing, interconnecting raw input voltages to feed active Fieldbus Modules and system controllers.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eP0926JMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eFoxboro (Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e102.2 cm x 12.4 cm x 12.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePass-through backplane distribution infrastructure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e100-240 V AC (+\/-15%) system feed input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC regulated backplane rail distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e5 A continuous capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power\u003c\/td\u003e\n\u003ctd\u003e120 W maximum rated distribution load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;90% (at 230 V AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Regulation\u003c\/td\u003e\n\u003ctd\u003e+\/-1% line and load regulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections\u003c\/td\u003e\n\u003ctd\u003eOverload (110-150%), short-circuit auto-recovery, over-voltage (27-30 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP20 (cabinet installation required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; DCS Instrumentation Properties\u003c\/h3\u003e\n\u003cp\u003eThe baseplate assembly forms the primary structural backplane backbone, featuring integrated channel-to-channel and subsystem isolation paths to mitigate electromagnetic cross-talk and ground loop interference. The physical circuit traces are engineered to handle continuous multi-channel 4-20 mA HART loop protocol routing and distributed DC power distribution. Embedded power conditioning circuits suppress high-frequency ripple noise below 150 mVp-p, preserving the absolute analog measurement accuracy of attached input\/output modules under dynamic load variations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What type of cooling is required for this baseplate when populated with modules under maximum load?\u003c\/p\u003e\n\u003cp\u003eA: The physical structure relies entirely on natural convection cooling. Populated assemblies must be enclosed within a climate-controlled IP20 cabinet that permits unobstructed vertical airflow to maintain ambient conditions between -40 and +70 deg C.\u003c\/p\u003e\n\u003cp\u003eQ: How does the baseplate infrastructure handle localized electrical faults?\u003c\/p\u003e\n\u003cp\u003eA: The integrated backplane architecture incorporates automated protection loops. Upon encountering an electrical short-circuit or an overload condition between 110% and 150% of rated capacity, the distribution rail engages auto-recovery logic to prevent transient damage to adjacent system components.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabinet Alignment:\u003c\/strong\u003e Install the baseplate assembly vertically or horizontally within the IP20 cabinet enclosure. Ensure all structural mounting fasteners are torque-tightened across the 102.2 cm span to prevent physical deflection or resonant vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Conductor Termination:\u003c\/strong\u003e Secure all incoming 100-240 V AC primary power distribution cables using verified low-impedance terminals. Confirm that the primary earth terminal is bonded directly to the main copper master ground bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Continuity:\u003c\/strong\u003e Maintain unbroken shield isolation layers for all field instrument cables routed near the baseplate. Keep low-voltage instrument wiring physically segregated from primary high-power distribution lines within the wire ducts.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":43454305337434,"sku":"P0926JMA","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/398._9dd4d88e-9341-475c-8d30-ba908bbd6cb0.jpg?v=1780623656","url":"https:\/\/www.spareoil.com\/products\/p0926jma-foxboro-dcs-system-baseplate-datasheet","provider":"SpareOil Automation","version":"1.0","type":"link"}