{"product_id":"pfcd-s5520-yokogawa-power-supply-module-new-original-stock","title":"PFCD-S5520 Yokogawa Power Supply Module | New \u0026 Original Stock","description":"\u003ch2\u003eYokogawa PFCD-S5520 CENTUM VP\/CS 3000 Power Supply Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa PFCD-S5520\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003ePFCD\u003c\/strong\u003e Field Control Station Power Supply Module, operates as a dedicated hardware component for regulated power distribution execution within CENTUM VP \/ CS 3000 FIO subsystems. The unit converts standard alternating current input into a stabilized direct current output plane to feed backplane-mounted tracking circuitry, logic cards, and associated field interface components.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePFCD-S5520\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg (Net) \/ 7.3 kg (Chassis Pack Shipping Weight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e130 x 107.5 x 32.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eInput: 100-240 VAC (50\/60 Hz), 1.0-0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC regulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003eUp to 5 A continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRipple \u0026amp; Noise\u003c\/td\u003e\n\u003ctd\u003eLess than 50 mVp-p\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e80 to 85% typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Features\u003c\/td\u003e\n\u003ctd\u003eOver-current, over-voltage, thermal shutdown, short-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Code\u003c\/td\u003e\n\u003ctd\u003eISA Standard G3 conformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThis assembly implements noise-filtered voltage modulation to prevent primary supply line fluctuations from destabilizing parallel 4-20 mA HART loop protocol elements. High-capacity galvanic isolation barriers partition the high-voltage AC input lines from the internal 24 VDC system backplane bus. This structural channel-to-system isolation absorbs inductive back-EMF spikes and blocks common-mode network ground ripples, containing electrical faults and sustaining cross-channel telemetry metrics across neighboring analog conversion sub-modules.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the PFCD-S5520 handle thermal dissipation under maximum continuous 5 A output loading?\u003c\/p\u003e\n\u003cp\u003eA: The module relies on localized physical housing vents and natural convection pathways for heat dissipation. The fanless design requires unobstructed vertical clearance inside the slot architecture to avoid initiating the internal thermal shutdown circuit when processing heavy current loads.\u003c\/p\u003e\n\u003cp\u003eQ: Can this power module be extracted or inserted while the remaining FIO baseplate elements are live?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The hardware accommodates active hot-swap procedures when arranged in a dual-redundant power configuration on an FIO baseplate. The backup power supply tracks system demand in real time, absorbing the full electrical load during a module exchange sequence with zero millisecond disruption to the system bus voltage.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInsert the power module into its designated baseplate slot allocation, pressing forward until the locking mechanism clicks onto the structural interface tracks.\u003c\/li\u003e\n\u003cli\u003eSeparate incoming AC source conductors from low-voltage instrument signals inside individual cabinet routing channels to minimize high-frequency electromagnetic coupling.\u003c\/li\u003e\n\u003cli\u003eConfirm that external grounding wires tie directly to the dedicated technical earth terminal of the chassis to ensure effective surge protection operations.\u003c\/li\u003e\n\u003cli\u003eMaintain clean air channels surrounding the module installation space to hold core temperatures below the +70 deg C operational threshold.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43510466150490,"sku":"PFCD-S5520","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/385._2e30c741-ebbd-43a2-866b-f7c219eef879.jpg?v=1781681418","url":"https:\/\/www.spareoil.com\/products\/pfcd-s5520-yokogawa-power-supply-module-new-original-stock","provider":"SpareOil Automation","version":"1.0","type":"link"}