{"product_id":"pn-45346-honeywell-tc-rpcxx01-redundant-power-module","title":"PN-45346 | Honeywell | TC-RPCXX01 Redundant Power Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTC-RPCXX01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Part Number\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePN-45346\u003c\/strong\u003e) is an authoritative redundant power supply module designed for the Honeywell Experion PKS and TDC 3000 Distributed Control System (DCS) platforms. This module is a mechanical necessity for high-availability process environments, providing stabilized and regulated 24 VDC power to system controllers and I\/O assemblies. It features a dual-input architecture that supports two independent AC sources with an automatic, seamless switchover mechanism. This ensures that a failure in a single power branch does not result in a process trip, making it a trustworthy choice for mission-critical operations in refineries, chemical plants, and utility power generation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTC-RPCXX01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePN-45346\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRedundant Power Supply Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell Experion PKS, TDC 3000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85–265 VAC (Universal Global Input)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (Regulated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRedundancy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual-input with automatic switchover circuitry\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOverload, Short-circuit, and Thermal protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25 °C to +70 °C (-13 °F to 158 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 °C to +85 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5% to 95% Non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e180 x 100 x 25 mm (Standard Form Factor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, UL, CSA Industrial Compliance\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering and Operational Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChassis Integration\u003c\/strong\u003e: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTC-RPCXX01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for installation in the standard Honeywell power chassis. Authoritative seating in the backplane is required to maintain the electrical integrity of the high-current DC rails.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy Strategy\u003c\/strong\u003e: To leverage full system availability, ensure that the primary and secondary AC inputs are derived from different power sources (e.g., Grid and UPS). The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePN-45346\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elogic will prioritize the primary feed and switch to the secondary within milliseconds upon detection of a voltage drop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management\u003c\/strong\u003e: In high-load configurations, the module generates heat as a byproduct of power regulation. Maintaining clear airflow within the cabinet is a mechanical necessity for long-term component health, especially when operating near the +70 °C upper limit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLoad Balancing\u003c\/strong\u003e: While the module features overload protection, engineers should calculate the total current draw of the downstream I\/O modules to ensure they remain within the rated capacity of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTC-RPCXX01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eassembly to ensure trustworthy operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if one of the AC inputs fails?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTC-RPCXX01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis engineered for seamless transition. The output 24 VDC remains within the tight regulation window, ensuring that controllers do not reset and data integrity is preserved across the DCS network.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module compatible with global power grids?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The universal input range of 85–265 VAC allows the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePN-45346\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto be deployed in any facility worldwide without the need for interposing voltage transformers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I hot-swap the TC-RPCXX01 module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module is designed for industrial use, but replacement protocols typically depend on your specific chassis configuration. For redundant setups, the secondary module will carry the load while the primary is serviced, provided the chassis backplane supports online removal.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43070381359194,"sku":"TC-RPCXX01 PN-45346","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/330._ecaeba13-525c-4e74-92c4-2597d0bf5e09.jpg?v=1773974406","url":"https:\/\/www.spareoil.com\/products\/pn-45346-honeywell-tc-rpcxx01-redundant-power-module","provider":"SpareOil Automation","version":"1.0","type":"link"}