{"product_id":"pr9376-010-011-epro-shaft-displacement-proximity-sensor","title":"PR9376\/010-011 EPRO Shaft Displacement Proximity Sensor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmerson EPRO PR9376\/010-011\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-precision, non-contact sensing element for advanced machinery protection systems. This 8mm eddy current probe measures relative shaft vibration, radial displacement, and eccentricity in critical rotating assets like turbines and high-speed compressors. Designed for seamless integration with EPRO CON signal converters (such as the CON021) and MMS\/AMS monitoring racks, it provides the primary data required for predictive maintenance. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Factory Sealed\u003c\/strong\u003e, ensuring original manufacturer accuracy for your industrial infrastructure.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe PR9376\/010-011 delivers consistent measurement performance under extreme thermal and mechanical stress.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProbe Tip Diameter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm (Standard)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 Meter (Fixed\/Integrated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.25 mm to 2.0 mm (Typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 °C to +180 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStainless Steel (Ruggedized)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCON021 Converter, MMS6000, MMS3000 Systems\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResistance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTurbine Oil, Dust, and High-Pressure Environments\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConditioned Voltage (via external converter)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNon-Contact Precision:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe probe utilizes electromagnetic induction to monitor the distance to the target shaft. This eliminates mechanical friction and wear, allowing for continuous monitoring at surface speeds that would destroy contact-based sensors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized for Tight Spaces:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1.0-meter fixed cable suits installations with limited mounting clearance or nearby junction boxes. This shorter length minimizes cable management complexity and reduces the risk of snagging during routine maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Thermal Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe PR9376\/010-011 withstands temperatures up to 180 °C. This rating permits direct mounting inside turbine housings and near hot bearings where standard electronics typically fail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEMI\/RFI Immunity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-quality shielding within the integrated cable rejects electromagnetic interference from surrounding high-voltage equipment, ensuring your vibration data remains accurate and free from electrical noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the PR9376\/010-011 require an external driver?\u003c\/strong\u003eYes. Like all passive eddy current probes, the PR9376\/010-011 requires a signal converter (driver) such as the EPRO CON021. The converter provides the excitation voltage and translates the probe's return signal into a 0-10V or 4-20mA industrial signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I extend the 1-meter cable?\u003c\/strong\u003eThe 1.0-meter cable length is factory-fixed and factored into the sensor's calibration. If your installation requires a longer reach, you must use a specific EPRO extension cable that matches the system's total required electrical length (typically 5m or 10m total). Never splice the cable manually.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I ensure the probe is correctly gapped during installation?\u003c\/strong\u003eMonitor the DC \"Gap Voltage\" at the signal converter while threading the probe into its mount. For most EPRO systems, adjust the probe until you achieve a stable -10V DC reading. This indicates the probe sits exactly in the center of its linear measurement range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this probe resistant to turbine lubricating oils?\u003c\/strong\u003eThe PR9376\/010-011 features a stainless steel body and a chemically resistant tip. It operates reliably while submerged in mineral or synthetic turbine oils and remains sealed against high-pressure environments common in oil-flooded bearings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":43151549661274,"sku":"PR9376\/010-011","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/402._660ed66d-a469-4c16-97ed-a4d309aed7a3.jpg?v=1774859882","url":"https:\/\/www.spareoil.com\/products\/pr9376-010-011-epro-shaft-displacement-proximity-sensor","provider":"SpareOil Automation","version":"1.0","type":"link"}