{"product_id":"pulse-input-analog-output-module-invensys-foxboro-p0400yg","title":"Pulse Input\/Analog Output Module | Invensys Foxboro P0400YG","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFoxboro P0400YG (FBM06)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance hybrid interface module designed for the Invensys I\/A Series Distributed Control System (DCS). It integrates four configurable pulse input channels with four 0–20 mA analog output channels, facilitating high-speed data acquisition from turbine meters, vortex meters, and rotating machinery. We offer this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal stock, ensuring immediate compatibility with redundant Fieldbus architectures and mission-critical control loops.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eP0400YG (FBM06)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Configurable Pulse Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Pulse Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12.5 kHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Analog Outputs (0 to 20 mA DC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Devices\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVortex\/Turbine meters, Solid state\/Electro-mechanical contacts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePer-channel optical isolation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRedundant Fieldbus (HDLC Protocol)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConfigurable Pulse Rate Input Resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–20 °C to +70 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, RoHS, UL Class I Div 2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Signal Conversion:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module accepts input rates up to 12.5 kHz, allowing precise tracking of rapid pulses from high-velocity turbine flowmeters without signal loss or aliasing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSmart Fail-Safe Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineers can configure independent \"Fail-Safe\" parameters for each channel. You can set the module to \"Hold\" the last value or \"Fallback\" to specific data points during a communication loss, protecting downstream actuators from erratic movements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Meter Scaling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe onboard application program executes Meter Scaling Factors directly at the module level. This reduces the processing load on the main controller and simplifies the integration of sensors with varied pulse-per-unit constants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Field Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOptical isolation for every channel shields the internal logic from electromagnetic interference (EMI) and field-side electrical surges common in power generation and heavy metallurgical environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant Fieldbus Connectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe P0400YG connects independently to the redundant Fieldbus. It manages switching times and enables seamless communication failover to maintain visibility of critical flow and event data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat types of sensors work with the P0400YG pulse inputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module accepts signals from vortex meters, turbine meters, dry contacts, open collectors, and TTL-compatible sensors. It supports signal voltages ranging from 5 VDC to 24 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace an older Revision of the P0400YG with this Rev-H unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The Rev-H designation indicates the latest hardware optimization. It maintains backward compatibility with existing I\/A Series baseplates while providing improved thermal and signal stability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the module handle output failures?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou can program the 0-20mA outputs to fall back to a predefined safety value if the Fieldbus connection drops, ensuring your actuators move to a known safe state.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this unit ready for immediate installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe ship all P0400YG modules in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econdition. They are ready for DIN rail or modular baseplate mounting and require standard I\/A Series engineering tools for final channel configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":43283933102170,"sku":"P0400YG FBM06","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/295._914e50b8-6644-49be-8b2e-c9ead43487a5.jpg?v=1777338609","url":"https:\/\/www.spareoil.com\/products\/pulse-input-analog-output-module-invensys-foxboro-p0400yg","provider":"SpareOil Automation","version":"1.0","type":"link"}