{"product_id":"pw482-50-s2-yokogawa-240vac-24vdc-5a-power-unit","title":"PW482-50 S2 Yokogawa | 240VAC 24VDC 5A Power Unit","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa PW482-50 S2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-reliability power conversion unit for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM CS3000 and CENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDistributed Control Systems (DCS). Specifically optimized for 220–240V AC environments, it provides regulated 24VDC power to process controllers, I\/O modules, and critical field interfaces. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, featuring the S2 revision for updated safety compliance and superior thermal resilience in extreme industrial climates.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown: PW482-50\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePW482\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e220 - 240 V AC Input with Temperature Option (-20 °C to 70 °C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e5\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExplosion Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard type with no explosion protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eType\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBasic type\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eS2\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRevision\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUpdated reliability and safety standard compliance\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePower Supply Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e220–240 V AC (50\/60 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC Regulated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.0 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRedundancy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports dual redundant load-sharing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 °C to +70 °C (Wide Temp Option)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.1 cm x 20.3 cm x 15.2 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.9 kg (Net) \/ 2.0 kg (Shipping)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStatus Indication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFront-panel Diagnostic LEDs (Status\/Fail)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtreme Climate Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike standard power modules limited to 50°C, the PW482-50 operates flawlessly from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-20°C to +70°C\u003c\/strong\u003e. This capability allows for installation in remote marshaling cabinets and outdoor shelters without requiring expensive HVAC overhead.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eActive Load-Sharing Redundancy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTwo PW482-50 S2 modules integrate seamlessly within a single CENTUM rack to provide a fault-tolerant power bus. If one unit fails, the redundant partner assumes the full electrical load instantly, preventing controller downtime and data loss.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRevision S2 Hardware Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe S2 revision incorporates modernized internal components that improve surge suppression and thermal efficiency. This update specifically targets the elimination of common-mode noise that can interfere with sensitive analog signal processing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swappable Functionality:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintenance engineers can replace a faulty module while the system remains live. The design ensures that extracting or inserting a module does not cause voltage dips on the backplane, maintaining 100% plant availability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use the PW482-50 S2 in a 110V AC system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The PW482-50 is specifically engineered for 220–240V AC inputs. For 110V AC environments, you must select the PW482-10 or PW401 series to match your site's electrical infrastructure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this module require manual configuration for redundant operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. When you seat two PW482-50 S2 modules into the same power rack, they automatically perform load sharing. The DCS backplane monitors the health of both units and generates an alarm if either unit deviates from safe operating parameters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this \"S2\" version backward compatible with my older \"S1\" racks?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The PW482-50 S2 serves as a direct drop-in replacement for legacy PW482 versions. It maintains the same physical form factor and electrical pinout while offering updated internal reliability standards.\u003c\/p\u003e\n\u003cp\u003eDo you need a single replacement unit or a full redundant pair to ensure zero-downtime operation?\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43337670623322,"sku":"PW482-50 S2","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/547..jpg?v=1778313711","url":"https:\/\/www.spareoil.com\/products\/pw482-50-s2-yokogawa-240vac-24vdc-5a-power-unit","provider":"SpareOil Automation","version":"1.0","type":"link"}