{"product_id":"qlcaiaan-siemens-apacs-quadlog-datasheet-technical-manual","title":"QLCAIAAN Siemens APACS+\/QuadLog Datasheet \u0026 Technical Manual","description":"\u003ch2\u003eSiemens QLCAIAAN APACS+\/QuadLog Critical Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for analog signal acquisition in APACS+ and QuadLog safety PLCs, the \u003cstrong\u003eSiemens QLCAIAAN\u003c\/strong\u003e (\u003cstrong\u003eQLCAIAAN\u003c\/strong\u003e Critical Analog Input Module), alternate part number \u003cstrong\u003e16437-30\/2\u003c\/strong\u003e or manufacturing part number \u003cstrong\u003eA5E00247442\/03\u003c\/strong\u003e, provides direct physical and electrical execution. The module samples current and voltage instrumentation data from field devices, processing these inputs via internal analog-to-digital converters to deliver digitized variable feedback directly to the system backplane network.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eQLCAIAAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens \/ Moore Products\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany \/ USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.19 lbs (0.54 kg) to 1.20 kg depending on packaging assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e90 x 90 x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e300 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Types\u003c\/td\u003e\n\u003ctd\u003eVoltage: 1-5 VDC; Current: 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Resolution\u003c\/td\u003e\n\u003ctd\u003e12-16 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd\u003e\\pm 0.1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Isolation\u003c\/td\u003e\n\u003ctd\u003eIntegrated galvanic protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirmware\/ROM Version\u003c\/td\u003e\n\u003ctd\u003e3.04 (variant dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eI\/O Density Scaling and Backplane Bus Communication\u003c\/h3\u003e\n\u003cp\u003eThe module utilizes high-density I\/O channel scaling architectures to interfaces 8 or 16 independent analog channels within a compact 90 mm width form factor, maximizing DIN-rail real estate in high-density control cabinets. Internal logic operations are locked to the backplane bus communication velocity licenses authorized by the APACS+ controller framework. Deterministic scanning intervals ensure synchronous data delivery across the local rack assembly without introducing processing jitter. The on-board processing unit maintains strict firmware flash compatibility with system ROM version 3.04, allowing seamless integration with legacy Moore Products architectures while suppressing system bus cross-talk during rapid multipoint signal transitions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the module handle a 4-20 mA loop failure or open-circuit condition?\u003c\/p\u003e\n\u003cp\u003eA: The module continuously monitors input current levels. When a signal drops below the standard 4 mA threshold (typically diagnosed at \u0026lt; 3.6 mA), the internal logic registers an under-range fault, updates the channel status word on the backplane, and triggers system-level diagnostics to alert the controller of potential loop failure or wire breaks.\u003c\/p\u003e\n\u003cp\u003eQ: Is hot-swapping permitted for the QLCAIAAN module during active system operation?\u003c\/p\u003e\n\u003cp\u003eA: Hot-swapping must comply strictly with the parent APACS+\/QuadLog rack deployment guidelines. While the hardware design mitigates backplane bus disruption during insertion or extraction, live maintenance should only be performed when the control loop is isolated or when the system architecture is configured for redundant fail-safe execution to prevent transient process disruptions.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure and Mounting Requirements:\u003c\/strong\u003e Secure the module on standard symmetric DIN-rails within an IP54 or higher rated industrial enclosure to mitigate dust, moisture, and particulate ingress. Maintain a minimum clear space of 50 mm above and below the module assembly to ensure optimal convective heat dissipation within the cabinet ambient range of -25 deg C to +70 deg C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring and Shield Terminations:\u003c\/strong\u003e Route all 4-20 mA and 1-5 VDC signal lines using twisted-pair shielded instrumentation cables. Terminate the cable shields exclusively at the designated cabinet single-point ground bus. Do not ground the shield at both ends to eliminate the formation of ground loops that degrade measurement accuracy below the specified \\pm 0.1% threshold.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Integrity:\u003c\/strong\u003e Connect the dedicated 24 VDC power feed using conductors rated for the 300 mA steady-state consumption load. Implement external fast-acting fuses or current-limiting circuit breakers on the primary supply line to safeguard internal components from transient overvoltage conditions and reverse-polarity events.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":43438496055386,"sku":"QLCAIAAN","price":90.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/201._009deda9-136b-419f-8490-f2984673026b.jpg?v=1780282078","url":"https:\/\/www.spareoil.com\/products\/qlcaiaan-siemens-apacs-quadlog-datasheet-technical-manual","provider":"SpareOil Automation","version":"1.0","type":"link"}