{"product_id":"redundant-i-o-8-point-sourcing-card-ab-1715-ob8de-controllogix","title":"Redundant I\/O 8-Point Sourcing Card | AB 1715-OB8DE ControlLogix","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Allen-Bradley 1715-OB8DE serves as an 8-point, dual-ended redundant digital output module purpose-built for mission-critical, fault-tolerant industrial applications. This hardware component delivers 24V DC sourcing (PNP) outputs to field devices where unexpected system shutdowns cause severe financial or operational loss. By incorporating two completely independent output circuits per physical channel, the module ensures that a failure on one internal path will not interrupt the field signal. It integrates directly into ControlLogix Redundant I\/O architectures via standard 1715 EtherNet\/IP adapter systems.\u003c\/p\u003e\n\u003cp\u003eWe guarantee this product arrives as a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New, original factory-sealed unit\u003c\/strong\u003e, ensuring untouched electronic components, pristine contact rails, and absolute physical integrity for high-availability process automation networks.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1715 Redundant I\/O System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1715-OB8DE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New Original Factory Sealed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8-Channel Sourcing (PNP) Digital Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRedundancy Architecture\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual-ended (two independent circuits drive one channel)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Sourcing Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 Volts DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 to 30 Volts DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContinuous Output Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTypically 0.5 Amps per channel (module limits apply)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSurge Protection Mechanisms\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated electronic circuit protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShort-Circuit Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eElectronic current-limiting protection per channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostic Capabilities\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePer-channel status and redundancy health monitoring\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFault Detection Engine\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDetects mismatches between redundant output sides\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Isolation Barriers\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eChannel-to-backplane electrical isolation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRequired Termination Base\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1715-TB or 1715-TBN standard wiring base\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNetwork Adapter Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1715-AENTR Redundant EtherNet\/IP Adapters\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 degrees Celsius (32 to 140 degrees Fahrenheit)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature Matrix\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 85 degrees Celsius (-40 to 185 degrees Fahrenheit)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRegulatory Compliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUL, CE, CSA, ATEX (revision specific)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEliminate Unplanned Downtime via Dual-Ended Paths:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTraditional output cards possess a single point of failure per channel. The 1715-OB8DE utilizes two parallel output circuits to drive a single solenoid or indicator, meaning the secondary circuit maintains constant current to the field device even if the primary path opens or shorts out.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolate Transient Faults with Per-Channel Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe on-board microprocessor monitors the health of both redundant halves continuously. It flags real-time circuit mismatches, tracking down field wiring degradation, open loads, and internal circuit deviations before a total channel loss occurs, speeding up preventative maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWithstand Electrical Back-EMF Spikes:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInductive loads like large control valves and contactor coils generate severe voltage spikes during de-energization. This module integrates robust electronic surge suppression into each sourcing channel, eliminating the need for external clamping diodes and saving rail space inside the control cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExecute Hot-Swaps Without Process Disruption:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe modular mechanical layout allows full removal and replacement of an active module while the sister system continues running. Technicians swap the hardware under live power without shutting down the main controller loop, maintaining continuous uptime in petrochemical and power generation facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat specific wiring bases must I purchase to install this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1715-OB8DE requires a separate dedicated termination base assembly. You must pair it with either the 1715-TB or 1715-TBN terminal base unit. These bases anchor the field-side wiring permanently, allowing you to slide the module on or off without disconnecting the field copper.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the 1715-OB8DE notify the system during an internal circuit failure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module utilizes built-in LED indicator lamps on the front faceplate to show individual channel status and overall redundancy health. Simultaneously, it transmits granular diagnostic data tags over the EtherNet\/IP network, alerting the ControlLogix processor to any hardware mismatches or localized line faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module operate alongside standard 1756 ControlLogix I\/O modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, but not in the same physical chassis. The 1715-OB8DE resides within its own dedicated 1715 remote I\/O rack. It passes data back to the primary 1756 ControlLogix processor chassis via a high-speed network link managed by 1715-AENTR redundant EtherNet\/IP communication adapters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":43392133038170,"sku":"1715-OB8DE","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/92._9fed0c64-1d21-4e7a-b95d-daffc9e01e91.jpg?v=1779157458","url":"https:\/\/www.spareoil.com\/products\/redundant-i-o-8-point-sourcing-card-ab-1715-ob8de-controllogix","provider":"SpareOil Automation","version":"1.0","type":"link"}