{"product_id":"redundant-programmable-controller-chassis-1756-a13-allen-bradley","title":"Redundant Programmable Controller Chassis | 1756-A13 Allen Bradley","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Allen Bradley 1756-A13 serves as a standard 13-slot modular chassis for large-scale automation architectures within the ControlLogix platform. This physical frame houses, supplies backplane power to, and facilitates data distribution between ControlLogix processors, dense I\/O modules, motion control cards, and high-bandwidth communication network modules. The hardware acts as the foundational backplane for plant-wide architectures, maximizing slot capacity inside a single rack to minimize multi-chassis bridge costs. We supply this product as a 100% brand new, factory-sealed unit in its original Rockwell Automation packaging to guarantee field-level electrical performance and long-term diagnostic durability.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen Bradley (Rockwell Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel Designation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1756-A13 ControlLogix\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCore Chassis Profile\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard High-Capacity Modular Rack\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAvailable Module Slots\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e13 Slots\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Orientation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePanel Mount Configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated Backplane Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-Speed Serial Communication Bus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBackplane Current Delivery (5.1 VDC)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15 Amperes Maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBackplane Current Delivery (1.2 VDC)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 Amperes Maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBackplane Current Delivery (24 VDC)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.8 Amperes Maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCompanion Power Supplies\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1756-PA, 1756-PB, 1756-PC, 1756-PD, 1756-PF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProcessor Series Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eControlLogix L6x, L7x, and L8x Systems\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperational Temperature Boundaries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 Degrees Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Temperature Boundaries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 85 Degrees Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnvironmental Humidity Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 to 95 Percent Non-Condensing Relative Humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Regulatory Compliance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUL, CE, CSA, ATEX, IECEx\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNet Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6.0 kg (13 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePhysical Envelope Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e584 x 132 x 280 mm (23 x 5.2 x 11 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eLarge process automation facilities and plant-wide EtherNet\/IP networks demand high-density module layouts that often strain network communication synchronization. The 1756-A13 resolves this issue by integrating a 13-slot high-speed serial backplane that delivers continuous, deterministic data paths between multiple controllers and complex communication modules inside the same local rack. This high-capacity design allows engineers to centralize main control loops, high-speed counters, and multiple network adapters (such as 1756-EN2TR cards) without installing extra chassis-to-chassis communication bridges that add data transmission latency.\u003c\/p\u003e\n\u003cp\u003eThe industrial-grade steel and aluminum chassis frame isolates internal printed circuit boards from structural machinery vibrations, protecting sensitive components against trace cracks and loose connections in harsh factory conditions. To simplify installation in busy electrical cabinets, the panel-mount base features pre-drilled layout holes and a dedicated chassis grounding lug. This grounding connection safely channels electrostatic discharge and high-frequency noise away from the processor logic bus.\u003c\/p\u003e\n\u003cp\u003eThe left-side universal power supply interface accepts a wide range of standard 1756 power modules, including AC, DC, and specialized redundant power supplies. By utilizing redundant power supply configurations on this 13-slot base, process engineers protect large, critical I\/O groupings from localized power outages. Furthermore, the standardized slot spacing provides open vertical ventilation channels, encouraging natural convection airflow to dissipate heat effectively even when the rack operates under full electrical loads at 60 Degrees Celsius.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan technicians mix older ControlLogix modules with newer L8x processors within the 1756-A13 chassis?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The 1756-A13 backplane maintains full backward and forward compatibility across the entire ControlLogix ecosystem. It allows the simultaneous installation of legacy L6x or L7x hardware alongside modern L8x series processors and advanced EtherNet\/IP communication interfaces without causing data corruption or slot interface conflicts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat installation steps prevent heat buildup when mounting a fully loaded 1756-A13 inside an enclosure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eField technicians must maintain a minimum clearance of 50.8 mm (2.0 in) along the top and bottom of the chassis, and 101.6 mm (4.0 in) along the sides. This spacing ensures proper convective airflow through the open ventilation channels, preventing the high-density module configurations from exceeding the maximum 60 Degrees Celsius operational temperature limit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this 13-slot chassis support hot-swapping (Removal and Insertion Under Power) for all standard modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1756-A13 chassis fully supports RIUP capabilities, allowing maintenance crews to replace malfunctioning I\/O or communication cards while the remaining modules continue to receive regulated power from the backplane. However, operators must follow plant safety guidelines regarding hazardous locations before changing modules under live electrical conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":43392581009498,"sku":"1756-A13","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/246._3b4f4f8c-f3be-450f-b91a-2754e2ea27d8.jpg?v=1779172830","url":"https:\/\/www.spareoil.com\/products\/redundant-programmable-controller-chassis-1756-a13-allen-bradley","provider":"SpareOil Automation","version":"1.0","type":"link"}