{"product_id":"rio-bus-interface-cards-yokogawa-and50-562-centum","title":"RIO Bus Interface Cards Yokogawa AND50-562 CENTUM","description":"\u003ch2\u003eYokogawa AND50-562 RIO Bus Interface Card\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa AND50-562\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eAND50-562\u003c\/strong\u003e RIO Bus Interface Card, operates as a dedicated hardware component for high-speed remote I\/O serial communication within Yokogawa distributed control systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAND50-562\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e100 mm x 120 mm x 25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC \/ 5 VDC backplane supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDual-Redundant RIO Bus Interface Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eRIO bus high-speed serial protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Speed\u003c\/td\u003e\n\u003ctd\u003e128 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Capabilities\u003c\/td\u003e\n\u003ctd\u003e16 digital points, 8 analog points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e1500 VAC withstand voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Options\u003c\/td\u003e\n\u003ctd\u003e19-inch rack mountable or DIN rail mountable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Isolation and HART Channel Integration\u003c\/h3\u003e\n\u003cp\u003eThe interface card routes high-speed data streams between Field Control Units (FCU) and remote I\/O station nodes across dual-redundant bus paths (Bus A and Bus B). Integrated signal conditioning provides 1500 VAC channel-to-channel and system galvanic isolation to mitigate ground loops and electromagnetic noise. This maintains transmission integrity for primary process variables, including 4-20 mA HART loop protocol signals and temperature inputs requiring digital cold junction compensation (CJC).\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the module handle communication failure on an active bus line?\u003c\/p\u003e\n\u003cp\u003eA: Internal hardware logic continuously monitors communication link health across Bus A and Bus B. If signal loss or data corruption occurs on the active channel, the card initiates an automatic hardware switchover to the secondary redundant path without disrupting I\/O process execution.\u003c\/p\u003e\n\u003cp\u003eQ: What are the primary installation requirements for maintaining galvanic isolation?\u003c\/p\u003e\n\u003cp\u003eA: Secure the card via its integrated rack or DIN rail mounting brackets, ensuring the metal grounding shield bonds directly to the enclosure protective earth. Field wiring and serial bus lines must remain physically separated from high-voltage AC cables to prevent induced noise on low-level signal paths.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure main power feeds are completely de-energized prior to inserting or removing the card from the interface nest. Align the board edges with the guide rails and push firmly to seat the backplane multi-pin connector. Tighten all retaining screws to establish low-impedance ground bonding and prevent mechanical disengagement under vibration. Terminate serial bus communication cables with approved matching connectors, observing strict single-point shield grounding protocols at the cabinet entry point.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43791488876634,"sku":"AND50-562","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/742..jpg?v=1785983322","url":"https:\/\/www.spareoil.com\/products\/rio-bus-interface-cards-yokogawa-and50-562-centum","provider":"SpareOil Automation","version":"1.0","type":"link"}