{"product_id":"safety-manager-field-termination-assembly-fc-tsdo-1624-honeywell","title":"Safety Manager Field Termination Assembly | FC-TSDO-1624 Honeywell","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell FC-TSDO-1624\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary physical bridge between the safety processor and critical field actuators. Designed specifically for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSafety Manager\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFail-Safe Controller (FSC)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatforms, this 16-channel Digital Output Field Termination Assembly (FTA) translates logic commands into 24 VDC signals. It drives solenoids, fire dampers, and alarms in high-integrity safety loops. We supply this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your safety instrumented system (SIS) operates with the precise millisecond response times required for SIL-rated protection.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFC-TSDO-1624\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Output Field Termination Assembly (FTA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannel Count\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Discrete Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 A per channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt; 10 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGalvanic Isolation (Field-to-System Bus)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndividual per-channel current limiting\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDedicated status and fault LEDs per channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–40 °C to +70 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, UL, CSA, SIL Compatible, Class I Div 2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSelective Fault Containment:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe FC-TSDO-1624 employs a per-channel current limiting architecture. If a short circuit occurs on one field device, the module isolates the specific channel. This prevents a localized fault from dragging down the 24 VDC bus, ensuring the remaining 15 channels continue to operate without interruption.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Actuation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith a response time of less than 10 milliseconds, this FTA ensures near-instantaneous execution of safety-critical actions. This rapid triggering is essential for pressure relief and emergency isolation valves (EIV) in volatile petrochemical processes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Troubleshooting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDedicated LED indicators provide immediate visual diagnostics for every output. Maintenance teams can identify active channels or specific wiring faults at a glance, significantly lowering the Mean Time to Repair (MTTR) during plant outages.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRuggedized Industrial Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe assembly operates across an extended thermal range of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e–40 °C to +70 °C\u003c\/strong\u003e. This allows for direct installation in unconditioned marshaling cabinets or Class I, Division 2 hazardous locations without the need for additional climate control hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSecure Field Termination:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module utilizes robust screw terminals for field wiring and a standardized SICC cable interface for the system connection. This design ensures vibration-resistant contacts and simplifies the replacement of legacy terminal blocks during system migrations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the FC-TSDO-1624 require external fuses for each channel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The module integrates individual current limiting for every channel. This electronic protection replaces traditional fuses, preventing a single field-side short from affecting the rest of the module or the safety processor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this FTA with Honeywell FSC (Fail-Safe Controller) systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The FC-TSDO-1624 is fully compatible with both the legacy Fail-Safe Controller (FSC) and the modern Safety Manager platforms, making it a versatile spare part for facility-wide safety system management.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum load the module can drive?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEach of the 16 channels supports a typical output current of 0.5 A at 24 VDC. This provides sufficient power to directly drive most industrial solenoids, relays, and signaling devices without interposing hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is \"Brand New\" status critical for an FTA?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eField Termination Assemblies are subject to environmental corrosion and terminal fatigue over time. A\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFC-TSDO-1624 ensures pristine galvanic isolation and zero oxidation on the screw terminals, maintaining the high-integrity signal path required for SIL 3 safety compliance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":42870916907098,"sku":"FC-TSDO-1624","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/33_4d505657-e284-4b8c-8506-2942b0964fec.jpg?v=1776328783","url":"https:\/\/www.spareoil.com\/products\/safety-manager-field-termination-assembly-fc-tsdo-1624-honeywell","provider":"SpareOil Automation","version":"1.0","type":"link"}