{"product_id":"schneider-electric-140avi03000-analog-input-module-plc","title":"Schneider Electric 140AVI03000 Analog Input Module PLC","description":"\u003ch2\u003eSchneider Electric 140AVI03000 Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-precision voltage sensing in Modicon Quantum PLC platforms, the \u003cstrong\u003eSchneider Electric 140AVI03000\u003c\/strong\u003e (\u003cstrong\u003e140AVI03000\u003c\/strong\u003e Analog Input Module) provides direct physical signal acquisition for differential voltage inputs within the control network.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e140AVI03000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eFrance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Quantum Format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e250 mA (Backplane current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8 Differential\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.05% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and Network Architecture\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e140AVI03000\u003c\/strong\u003e utilizes high-density differential inputs to mitigate common-mode noise across the Modicon Quantum backplane bus. To support deterministic I\/O density scaling, this module provides software-configurable voltage ranges (e.g., +\/- 10 V, 1-5 V) via the system configuration software. The module architecture features 1780 V AC galvanic isolation between input channels and the backplane, protecting the CPU from field-side voltage transients. Furthermore, the firmware supports configurable data filtering to manage backplane bus communication velocity, ensuring that analog signal updates remain synchronized with the PLC scan cycle.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 140AVI03000 be hot-swapped while the Quantum PLC is running?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports removal and insertion while the backplane is powered. Ensure that the associated I\/O mapping in the software is properly handled to prevent diagnostic faults or unexpected process states during the transition.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle signal scaling for different input ranges?\u003c\/p\u003e\n\u003cp\u003eA: The module resolution varies from 12-bit to 16-bit based on the range selected via the engineering software. Higher resolution is achieved on the +\/- 10 V and +\/- 5 V ranges, allowing for precise feedback from high-impedance field instruments.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Connection:\u003c\/strong\u003e Utilize the 40-pin removable terminal block (140XTS00200) for field wiring. Ensure each wire is properly crimped to prevent high-resistance contacts that could degrade the \u0026gt; 20 MΩ input impedance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e Terminate cable shields at the cabinet-integrated ground bus. Maintain a clean physical separation between analog signal cabling and high-power AC or VFD motor cables to prevent inductive EMI coupling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Sealing:\u003c\/strong\u003e The module is designed for operation within standard industrial enclosures. Avoid installation in environments exceeding 60 deg C, as this will accelerate internal component drift and reduce measurement accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration:\u003c\/strong\u003e Perform an annual calibration verification to ensure the 0.05% absolute accuracy is maintained, particularly in applications where the module interface connects to sensitive laboratory-grade sensors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSEO Suite\u003c\/h3\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":42870862315610,"sku":"140AVI03000","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/106_52c806b3-300c-445d-afed-62fc6019cb99.jpg?v=1772163198","url":"https:\/\/www.spareoil.com\/products\/schneider-electric-140avi03000-analog-input-module-plc","provider":"SpareOil Automation","version":"1.0","type":"link"}