{"product_id":"sdv541-s13-yokogawa-centum-vp-digital-output-module","title":"SDV541-S13 YOKOGAWA CENTUM VP Digital Output Module","description":"\u003ch1\u003eYOKOGAWA SDV541-S13 Digital Output Module\u003c\/h1\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYOKOGAWA SDV541-S13\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSDV541\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDigital Output Module, operates as a dedicated hardware component for deterministic digital output switching within CENTUM VP DCS and ProSafe-RS SIS platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSDV541-S13\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYOKOGAWA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eJapan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.36 to 0.41 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e130 x 107.5 x 32.8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Industrial Specification\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e290 mA (5 VDC backplane), 140 mA (24 VDC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 isolated channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo-voltage contact output\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eContact Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (+20% \/ -10%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResponse Time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;= 40 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIsolation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 kVAC (signal to system, 1 min)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProcess Control and DCS Instrumentation Integrity\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYOKOGAWA SDV541-S13\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizes sophisticated channel-to-channel isolation architecture to prevent fault propagation across critical control loops. In the context of ProSafe-RS SIS integration, the module facilitates precise loop management through 16 isolated channels. The internal circuitry provides comprehensive diagnostic self-monitoring, which communicates status directly to the host controller to ensure signal integrity during state transitions. Cold junction compensation is not applicable to this digital output module; however, the hardware maintains strict electrical isolation to mitigate common-mode noise interference typical in high-density DCS environments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Does the SDV541-S13 support hot-swapping in a redundant configuration?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports hot replacement capability when installed within compatible baseplates in a redundant rack arrangement, allowing for maintenance without interrupting the primary process control cycle.\u003c\/p\u003e\n\u003cp\u003eQ: What are the specific power requirements for the backplane connection?\u003c\/p\u003e\n\u003cp\u003eA: The module draws a maximum of 290 mA from the 5 VDC backplane bus and requires an auxiliary 24 VDC external supply with a maximum consumption of 140 mA for output operation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSecure the module into the designated Compact FIO baseplate. Ensure the module is fully seated until the mechanical locking mechanism engages to prevent intermittent connection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilize shielded twisted-pair cabling for all signal connections to maintain 2 kVAC isolation integrity. Ensure the shield is grounded at the designated common point to minimize electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTermination:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVerify that the field wiring terminal configuration matches the specific S13 hardware revision to prevent voltage mismatch at the contact outputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePrior to installation or removal, ensure the associated system segment is de-energized or placed in bypass mode if the logic solver allows, to prevent inadvertent actuation of field solenoids or relays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43611312029786,"sku":"SDV541-S13","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/95_8c943ef3-9f7f-4138-a736-986dda54c66c.jpg?v=1783392240","url":"https:\/\/www.spareoil.com\/products\/sdv541-s13-yokogawa-centum-vp-digital-output-module","provider":"SpareOil Automation","version":"1.0","type":"link"}