{"product_id":"tc-batt01-honeywell-tdc-3000-process-controller-battery","title":"TC-BATT01 Honeywell TDC 3000 Process Controller Battery","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell TC-BATT01 maintains data integrity and volatile memory retention inside distributed control systems (DCS) during primary power failures. This high-capacity hardware module provides a dependable energy bridge, allowing process controllers to execute orderly shutdowns or shift operations to redundant hardware components without erasing critical software configurations or real-time process state variables. It targets critical, high-availability industries like petrochemical refining and power generation where power drops can cause severe operational downtime. To protect critical process applications from unverified component degradation, this shipment delivers 100% brand new, original factory-packaged backup modules.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTC-BATT01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFactory Part Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51197593-100\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Classification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBattery Backup Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eControl System Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell Experion PKS and TDC 3000 Platforms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBattery Chemistry Core\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSealed Rechargeable Ni-Cd or Lithium Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Voltage Curve\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConfigured to native controller backplane requirements\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBackup Runtime Duration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSeveral minutes minimum depending on active processor load\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRecharge Mechanism\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAutomatic replenishment via standard system power supply\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated Diagnostics\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eContinuous automated battery health monitoring loops\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 50 degrees Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Temperature Limits\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to 45 degrees Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePermissible Ambient Humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 percent to 95 percent non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNet Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 to 0.7 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial Compliance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, UL, and CSA Certifications\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe TC-BATT01 eliminates the risk of catastrophic data loss by delivering continuous electrical current to active memory circuits when the primary power grid drops. Standard backup solutions often require system shutdown for maintenance, but this module allows hot-swapping inside standard Experion PKS chassis slots. Technicians slide the module along the integrated chassis guide rails and connect it directly onto the live backplane without disrupting ongoing process control loops. The mechanical frame features heavy-duty integrated retaining screws that anchor the module tightly against the backplane, blocking severe plant vibrations from loosening the power connection.\u003c\/p\u003e\n\u003cp\u003eThe internal electrical design includes an automated self-diagnostic monitoring circuit that interfaces directly with the Experion System Management Console. The DCS queries the module continuously, streaming real-time data regarding voltage levels, charge readiness, and cell depletion profiles directly to the operator interface. This early warning system eliminates manual battery testing routines and alerts control room personnel before the cells reach critical exhaustion levels. Furthermore, the internal charging circuit uses the main chassis power supply to manage cell replenishment, maintaining optimal charge curves without requiring external charging equipment.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat specific fault indicators appear if the TC-BATT01 fails while the factory floor is operational?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIf primary power remains stable, a depleted or failing TC-BATT01 module will not interrupt active process loops. Instead, the central controller triggers a \"Battery Low\" or \"Battery Fault\" diagnostic alarm inside the Experion System Management Console. This notification warns maintenance teams that the specific controller slot no longer possesses backup protection, requiring immediate module replacement to restore system redundancy before a main power disruption occurs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this battery pack supply backup electrical power to all cards inside the shared DCS chassis?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 51197593-100 battery pack targets the specific processor and volatile memory circuits of its assigned controller slot. It preserves critical ladder logic, custom control strategies, and real-time historical data buffers inside the local CPU RAM during a blackout, rather than powering field I\/O terminations or auxiliary communication cards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat commissioning steps must engineers complete when installing a brand new module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAfter sliding the new module into the backup slot and fastening the retaining screws, you must keep the chassis energized for at least 24 hours. This initial startup window allows the integrated power supply to complete its automated charging cycle, bringing the new cell core up to maximum operational capacity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43068038709338,"sku":"TC-BATT01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/313.1.jpg?v=1773912427","url":"https:\/\/www.spareoil.com\/products\/tc-batt01-honeywell-tdc-3000-process-controller-battery","provider":"SpareOil Automation","version":"1.0","type":"link"}