{"product_id":"tc-ixr061-honeywell-6-channel-isolated-rtd-module-new-original-stock","title":"TC-IXR061 Honeywell 6-Channel Isolated RTD Module | New \u0026 Original Stock","description":"\u003ch2\u003eHoneywell TC-IXR061 Experion Isolated RTD Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-precision temperature loop monitoring in Experion PKS and LS series control architectures, the \u003cstrong\u003eHoneywell TC-IXR061\u003c\/strong\u003e (\u003cstrong\u003eTC-IXR061\u003c\/strong\u003e Isolated Analog Input Module) provides direct physical\/electrical execution. The hardware operates 6 fully independent galvanically isolated channels that convert analog signals derived from resistance temperature detectors (RTDs) and low-level resistance sources into digitized data registers. By maintaining complete channel-to-channel and channel-to-bus electrical barriers, the card stops ground loop currents from destabilizing measurement values across the industrial grid.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTC-IXR061\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.30 kg (2.86 lbs) shipping allocation mass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Experion PKS chassis plug-in form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e4.3 W maximum internal heat output loading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Points\u003c\/td\u003e\n\u003ctd\u003e6 galvanically isolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Update Rate\u003c\/td\u003e\n\u003ctd\u003e50 ms simultaneous sampling across all channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Bandwidth\u003c\/td\u003e\n\u003ctd\u003eDC to 15 Hz (-3 dB point)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen Wire Detection\u003c\/td\u003e\n\u003ctd\u003eTriggered and logged within 5 seconds (forces out-of-range flag)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRFI Immunity\u003c\/td\u003e\n\u003ctd\u003eMeasurement error \u0026lt; 2.0% at 10 V\/m field strength (27 to 1000 MHz span)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssociated Terminal\u003c\/td\u003e\n\u003ctd\u003eTC_TBNH (20-position terminal block connection component)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell TC-IXR061 establishes rigorous channel-to-channel isolation parameters to handle low-voltage sensor values in transient-heavy processing sectors. The internal architecture matches these physical boundaries with an active analog front end that restricts signal coupling between processing tracks.\u003c\/p\u003e\n\u003cp\u003eWhile built primarily for RTD resistance monitoring rather than active 4-20 mA HART loop protocol loops, the high-grade galvanic isolation design ensures that adjacent high-current loops do not leak charge across the input multiplexer arrays. The localized DC to 15 Hz low-pass filtering stage provides sharp attenuation of industrial frequency hum, sustaining stable temperature measurements even when sensor lines run adjacent to high-power distribution corridors.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the open-wire detection logic behave when an RTD lead snaps or breaks under stress?\u003c\/p\u003e\n\u003cp\u003eA: The module applies a microscopic constant current to monitor lead wire integrity. If a conductor snaps or detaches, the circuit senses an infinite resistance condition and asserts an out-of-range error code onto the host platform registers within 5 seconds, notifying the master logic to trip appropriate sensor-fault interlocks.\u003c\/p\u003e\n\u003cp\u003eQ: Can the TC-IXR061 accept mixed configurations of 2-wire, 3-wire, and 4-wire RTD sensors simultaneously across its 6 channels?\u003c\/p\u003e\n\u003cp\u003eA: Yes. Because every channel features independent channel-to-channel isolation and dedicated pin processing maps, the module permits distinct wiring formats on each input terminal group, provided the correct resistance mapping templates are active in the controller's channel profile parameters.\u003c\/p\u003e\n\u003cp\u003eQ: Does this module support live extraction and insertion (hot-swapping) while the Experion controller rack is under power?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The Experion PKS chassis includes active backplane pin alignment that allows the TC-IXR061 to be swapped out during active operations without shutting down processing power or disrupting data frames on adjacent I\/O modules.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIsolate all external sensor wiring loops from potential short circuits before plugging the input card into the chassis guide rails.\u003c\/li\u003e\n\u003cli\u003eSlide the module into its assigned slot on the Experion PKS chassis frame, pushing backward until the rear multi-point connector block seats into the rack backplane assembly.\u003c\/li\u003e\n\u003cli\u003eMount the designated TC_TBNH 20-position terminal block onto the front interface of the module and secure the integration latches.\u003c\/li\u003e\n\u003cli\u003eTerminate RTD field elements using high-quality shielded twisted cables, ensuring the shield braid links directly to the cabinet ground bar and is isolated at the sensor housing.\u003c\/li\u003e\n\u003cli\u003eMaintain at least 30 cm of clearance between the RTD instrument signal wires and any high-voltage AC distribution circuits or variable speed drive conductors to preserve RFI immunity standards.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":42870825713754,"sku":"TC-IXR061","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/61_b8a6f031-23c8-4a42-9860-b0e3ce873d77.jpg?v=1770687647","url":"https:\/\/www.spareoil.com\/products\/tc-ixr061-honeywell-6-channel-isolated-rtd-module-new-original-stock","provider":"SpareOil Automation","version":"1.0","type":"link"}