{"product_id":"tc-oav081-honeywell-experion-series-c-8-channel-analog-output","title":"TC-OAV081 Honeywell Experion Series C 8-Channel Analog Output","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell TC-OAV081\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-performance analog output interface within the Experion PKS Series C I\/O ecosystem. This module provides eight independent channels to modulate critical field equipment, including control valves, variable speed drives (VSDs), and industrial actuators. It delivers both voltage (±10.4 VDC) and current (0–21 mA) signals with deterministic precision. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your DCS (Distributed Control System) maintains peak loop stability and response accuracy.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe TC-OAV081 utilizes high-resolution digital-to-analog conversion to ensure exact process setpoint tracking:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExperion PKS Series C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Independent Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±10.4 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0–21 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e320 µV (Voltage) \/ 0.650 µA (Current) per count\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCalibration Accuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBetter than 0.05% of range (at 25°C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUpdate Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25 ms for all channels (Deterministic)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSettling Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;2 ms to 95% (Resistive load)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Load Impedance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e750 Ω (Current mode)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2550 VDC for 1 second (User-to-System)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOvervoltage Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VAC\/VDC protection with current limiting\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRequired Terminal\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTC-TBNH 20-position block\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe TC-OAV081 addresses the rigorous demands of modern process industries through advanced hardware engineering:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic Control Response:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module updates all eight channels every 25ms. This fixed update rate ensures predictable behavior in fast-acting control loops, such as steam turbine bypass valves or high-pressure gas regulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Signal Fidelity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith a resolution of 0.650 µA per count, the TC-OAV081 provides granular control over valve positioning. This precision reduces process oscillations and minimizes mechanical wear on actuators caused by signal jitter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExceptional Electrical Hardening:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSystem-to-user isolation at 2550 VDC prevents field-side electrical surges from damaging the Experion PKS backplane. Integrated electronic current limiting at 21 mA protects the module internal circuitry against accidental short circuits in field wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Output Modes:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOperators configure individual channels for either voltage or current modes. This dual-capability eliminates the need for separate hardware inventories for different actuator signal types, simplifying spare parts management.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the TC-OAV081 include the terminal block?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The module requires a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTC-TBNH 20-position terminal block\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor field wiring, which you must order separately to complete the installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module replace legacy Series A or B analog output units?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe TC-OAV081 is specific to the Experion PKS Series C hardware profile. While it performs similar functional roles, you must ensure your I\/O rack and controller firmware support Series C modules before attempting a migration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if a field wire shorts to a 24V source?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module includes built-in 24 VAC\/VDC overvoltage protection. This safety feature suppresses the surge and limits current to 21 mA, preventing the \"cascading failure\" of the entire I\/O rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this unit compatible with HART protocol?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe TC-OAV081 is a standard analog output module. For applications requiring HART digital communication for valve diagnostics, we recommend verifying the specific Honeywell HART-enabled AO variant (e.g., TC-HAI or similar Series C modules).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":42870825418842,"sku":"TC-OAV081","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/327_823d52e3-26ec-4432-8e8e-c3c70f21a02e.jpg?v=1772675695","url":"https:\/\/www.spareoil.com\/products\/tc-oav081-honeywell-experion-series-c-8-channel-analog-output","provider":"SpareOil Automation","version":"1.0","type":"link"}