{"product_id":"triconex-3806e-analog-output-module-tmr-safety","title":"Triconex 3806E Analog Output Module | TMR Safety","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTriconex 3806E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as a high-integrity\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAnalog Output Module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the most demanding Safety Instrumented Systems (SIS). This\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal module utilizes a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTriple Modular Redundancy (TMR)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitecture to provide fault-tolerant control of critical field actuators. Unlike standard analog cards, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3806E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoffers a unique mixed-output configuration, combining conventional 4-20 mA signals with specialized 20-320 mA high-current outputs. This dual-capability makes it the industry standard for governing hydraulic actuators in turbomachinery and complex process safety loops where precision and power must coexist.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e3806E\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStandard Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 × 4–20 mA DC Analog Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHigh-Current Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 × 20–320 mA DC Analog Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eArchitecture\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTriple Modular Redundancy (TMR)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSIL 3 Compliant (IEC 61508)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 °C to +70 °C (-40 °F to 158 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVibration Resistance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5–500 Hz, 2 g (X\/Y\/Z axes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShock Resistance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 g, 11 ms duration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Triconex TMR I\/O Racks\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.55kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDynamic Mixed-Signal Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3806E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eeliminates the need for separate high-power modules by integrating six standard 4-20 mA loops and two 20-320 mA loops. This allows engineers to control standard control valves and high-demand torque motors or hydraulic positioners from a single module slot.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTriple Modular Redundant Fault Tolerance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThree independent internal processing legs vote on every output signal. If one path fails, the 2oo3 (two-out-of-three) voting logic ensures the remaining two legs maintain control without an output glitch, preventing costly nuisance trips in turbomachinery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtreme Environment Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineered for survival, the module operates reliably from -40 °C to +70 °C. This ruggedized design suits remote oil and gas installations and power generation facilities where temperature control in equipment shelters may vary.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Precision Actuator Command:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 16-bit internal resolution provides the granular control necessary for anti-surge valves and fuel gas regulators. This precision directly translates to better process stability and reduced mechanical wear on expensive valve assemblies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eComprehensive Load Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module continuously monitors the health of the output loops. It detects open circuits and short circuits in the field wiring and reports these faults immediately to the Tricon CPU, enabling proactive maintenance before a safety event occurs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the high-current 20-320 mA outputs for standard 4-20 mA devices?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTechnically, the range is configurable, but the 20-320 mA channels are specifically optimized for devices requiring higher drive current, such as specialized hydraulic proportional valves. Always verify your device's impedance and current requirements before connection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 3806E compatible with older Triconex chassis?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3806E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einstalls into standard Triconex TMR I\/O racks. However, you must verify your Tricon CPU firmware and software version (TriStation 1131) to ensure the system supports the high-density mixed-output configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat precautions should I take for long-distance wiring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDue to the high-current capability of the 320 mA channels, ensure your cable gauge minimizes voltage drop. Use high-quality shielded twisted-pair cabling to prevent electromagnetic interference from affecting the 4-20 mA precision loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":43107667771482,"sku":"3806E","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/425._2a7412db-3308-4efb-a0bb-21b864bc6506.jpg?v=1774346026","url":"https:\/\/www.spareoil.com\/products\/triconex-3806e-analog-output-module-tmr-safety","provider":"SpareOil Automation","version":"1.0","type":"link"}