{"product_id":"tsx-map-1074-schneider-modicon-tsx-micro-datasheet-technical-manual","title":"TSX-MAP-1074 Schneider Modicon TSX Micro Datasheet Technical Manual","description":"\u003ch2\u003eSchneider TSX-MAP-1074 Modicon TSX Micro Communication Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSchneider TSX-MAP-1074\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eTSXMAP1074\u003c\/strong\u003e Modbus Plus Communication Adapter, operates as a dedicated hardware component for MAPWAY data link interface management within Modicon TSX Micro PLC systems. The hardware establishes communication synchronization parameters over high-speed networks, allowing the host controller to exchange variables, logic interlocks, and supervisory frames across peer-to-peer or multi-drop architectures. Execution of network physical layers is managed by localized co-processing chips embedded on the plug-in board assembly.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTSX-MAP-1074\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eFrance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.30 kg (0.66 lbs) net weight \/ 1.14 kg (2.51 lbs) shipping weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e120 mm x 40 mm x 90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDerived from TSX Micro backplane power rails\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Type\u003c\/td\u003e\n\u003ctd\u003eModbus Plus \/ MAPWAY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Speed\u003c\/td\u003e\n\u003ctd\u003e1 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003e1 x Modbus Plus network connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Topology\u003c\/td\u003e\n\u003ctd\u003ePeer-to-peer, multi-drop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNode Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 64 nodes per network segment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eDedicated LED array for network activity and module status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe Schneider TSX-MAP-1074 functions inside the modular assembly by translating system variables across the interior architecture under backplane bus communication velocity licenses. Data traffic handling runs deterministically at 1 Mbps using a token-passing mechanism, preventing data collisions across the continuous multi-drop routing path.\u003c\/p\u003e\n\u003cp\u003eWhen aligning historical networks with modern Profinet \/ EtherNet\/IP deterministic networks via external system bridges, the interface preserves the integrity of localized data packets. This structure supports precise I\/O density scaling profiles up to 64 nodes, guaranteeing that high-frequency registry polling sequences maintain sub-millisecond repeatability criteria without degrading internal processing memory buffers.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the TSX-MAP-1074 module be extracted or inserted into the rack slot while backplane power is active?\u003c\/p\u003e\n\u003cp\u003eA: No. The TSX Micro slot architecture does not feature live insertion protection circuitry. Performing hot-swap actions can generate destructive transient voltage spikes across the data pins, risking physical failure of the internal communication processors.\u003c\/p\u003e\n\u003cp\u003eQ: How does the network logic respond if two nodes are assigned identical addresses on the same segment?\u003c\/p\u003e\n\u003cp\u003eA: Address duplication induces token errors and drops the duplicate nodes offline. The status diagnostics will display error indicators, and communication processing across the affected hardware terminals will be suspended until the rotary address parameters are corrected.\u003c\/p\u003e\n\u003cp\u003eQ: Does this hardware configuration support direct connectivity to Modicon Quantum or M580 backplanes?\u003c\/p\u003e\n\u003cp\u003eA: No. The physical connector spacing and bus line pins are engineered strictly for the Modicon TSX Micro hardware platform. It cannot be inserted or operated inside Quantum or X80 chassis configurations.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect all electrical current loops feeding the primary PLC rack prior to sliding the communication card into its slot.\u003c\/li\u003e\n\u003cli\u003eSlide the plug-in module firmly into the TSX Micro chassis guide until the backplane interface seats entirely into the socket pins.\u003c\/li\u003e\n\u003cli\u003eLock the integrated mechanical fasteners to ensure electrical continuity with the protective earth terminal of the rack frame.\u003c\/li\u003e\n\u003cli\u003eWire the Modbus Plus trunk line with specific shielded twisted-pair media, terminating the ends with appropriate 120 Ohm balancing resistors to avoid signal reflection.\u003c\/li\u003e\n\u003cli\u003eRoute all data networking cables through metallic wire ways separated from primary AC supply runs by at least 30 cm to suppress magnetic cross-coupling.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":43447581605978,"sku":"TSXMAP1074","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/176._a17df568-1c9c-4fb3-9628-1dc520c0ac76.jpg?v=1780465270","url":"https:\/\/www.spareoil.com\/products\/tsx-map-1074-schneider-modicon-tsx-micro-datasheet-technical-manual","provider":"SpareOil Automation","version":"1.0","type":"link"}