{"product_id":"tsxaey1600-schneider-electric-16-channel-analog-input-module","title":"TSXAEY1600 Schneider Electric 16-Channel Analog Input Module","description":"\u003ch2\u003eSchneider Electric TSXAEY1600 Modicon Premium Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for precise analog-to-digital conversion in Modicon Premium PLC platforms, the \u003cstrong\u003eSchneider Electric TSXAEY1600\u003c\/strong\u003e (\u003cstrong\u003eTSXAEY1600\u003c\/strong\u003e Analog Input Module) provides direct physical\/electrical execution. The hardware executes multi-channel signal acquisition across 16 independent analog inputs, accommodating both high-level voltage (0 to 10 V, +\/-10 V, +\/-5 V, 1 to 5 V) and loop current (0 to 20 mA, 4 to 20 mA, +\/-20 mA) configurations. The module processes field transmitter variables using a successive approximation converter architecture, rendering data into 12-bit digital words for real-time backplane processing.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTSXAEY1600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eFrance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.34 kg (0.75 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Modicon Premium module format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e270 mA at 5 VDC (~1.5 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Time\u003c\/td\u003e\n\u003ctd\u003e~1 ms per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e1 MΩ (voltage mode), 250 Ω (current mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.3% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Protection\u003c\/td\u003e\n\u003ctd\u003e+\/-30 V (voltage mode), +\/-30 mA (current mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFirmware Flash Compatibility and Backplane Communication\u003c\/h3\u003e\n\u003cp\u003eThe internal microprocessor controls data synchronization to ensure alignment with the host controller firmware flash compatibility matrix. Field-side variables undergo continuous analog filtering before being passed across the electrically isolated backplane bus network interface. The hardware handles high channel density scaling through dedicated logic loops, preventing transmission latencies or signal degradation from impacting the master PLC rack during concurrent 16-channel measurement scans.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the module handle a sustained overcurrent condition on a 4-20 mA input loop?\u003c\/p\u003e\n\u003cp\u003eA: The input circuitry features active hardware protection that tolerates a continuous overcurrent up to +\/-30 mA at state 1 across the internal 250 Ohm resistor without causing degradation to adjacent channels.\u003c\/p\u003e\n\u003cp\u003eQ: Is channel-to-channel isolation provided on this hardware assembly?\u003c\/p\u003e\n\u003cp\u003eA: The module provides robust isolation between the aggregate field channels and the internal bus, as well as between channels and chassis ground. However, the 16 analog inputs share a common reference ground point within the module circuitry.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInsert the module into the designated slot of the Modicon Premium rack and verify that the rear ground fingers make positive contact with the chassis before tightening the retaining screws.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted pair (STP) cabling for all analog voltage and current loops, grounding the shield exclusively at the marshalling panel or rack ground bar.\u003c\/li\u003e\n\u003cli\u003eSeparate low-signal analog input runs from high-voltage AC motor control lines and switching inductive loads to limit electromagnetic noise coupling.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":43536784883802,"sku":"TSXAEY1600","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/216._8e02b480-551f-434c-80a2-3c9d13d410b8.jpg?v=1782181240","url":"https:\/\/www.spareoil.com\/products\/tsxaey1600-schneider-electric-16-channel-analog-input-module","provider":"SpareOil Automation","version":"1.0","type":"link"}