{"product_id":"tsxpsy2600m-schneider-electric-power-supply-module-new-original-stock","title":"TSXPSY2600M Schneider Electric Power Supply Module | New \u0026 Original Stock","description":"\u003ch2\u003eSchneider Electric TSXPSY2600M Modicon Premium Power Supply Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-efficiency primary voltage regulation in industrial control networks, the \u003cstrong\u003eSchneider Electric TSXPSY2600M\u003c\/strong\u003e (\u003cstrong\u003eTSXPSY2600M\u003c\/strong\u003e Power Supply Module) provides direct physical\/electrical execution. This hardware component processes AC input ranges to deliver multiple isolated, regulated DC rails directly to the local backplane bus. By serving as the central power distribution node for processor and I\/O modules installed on a standard chassis, this unit maintains continuous internal logic execution and sensor-loop bias without introducing voltage fluctuations into the communication backplane layer.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTSXPSY2600M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eModicon Premium \/ TSX Micro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003ePower Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Input Voltage\u003c\/td\u003e\n\u003ctd\u003e100 to 240 V AC (Operational limits: 85 to 264 V AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz (Operational limits: 47 to 63 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e300 mA at 240 V AC, 500 mA at 100 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e37 A at 100 V AC, 75 A at 240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary Power Output\u003c\/td\u003e\n\u003ctd\u003eTotal 26 W (5 V DC at 5 A, 24 V DC sensor at 0.5 A, 24 V DC relay at 0.6 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Protection\u003c\/td\u003e\n\u003ctd\u003eInternal 4 A fuse, overload protection, overvoltage protection, short-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Status Diagnostics\u003c\/td\u003e\n\u003ctd\u003eGreen LED (24 V sensor voltage), Green LED (OK), Red LED (battery fault)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e10 to 95 percent non-condensing (Operation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003ePollution degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.51 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL 508, CSA, IEC 61131-2, ABS, DNV, LR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Protection Overlays\u003c\/h3\u003e\n\u003cp\u003eThis power supply module integrates a high-speed backplane interface that preserves internal bus communication velocity by filtering out high-frequency transient noise generated by surrounding switched-mode equipment. The internal architecture utilizes separate physical transformer windings to isolate the 5 V DC logic rail from the 24 V DC field and relay supply circuits, establishing rigorous channel-to-channel isolation. This structure prevents field-side short circuits or ground faults from dropping the main CPU bus voltage. An embedded watchdog circuit monitors the secondary voltages, forcing all output rails into a shutdown state within milliseconds if an overvoltage condition is detected, safeguarding the internal memory and firmware flash systems of adjacent modules.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What specific field faults trigger the red battery fault LED indicator? A: The red battery fault LED illuminates when the internal backup battery voltage drops below the minimum threshold required to maintain the volatile CMOS memory and real-time clock parameters of the associated CPU module during a primary power interruption.\u003c\/p\u003e\n\u003cp\u003eQ: Can this power supply drive external inductive loads directly from its 24 V DC relay output? A: The 24 V DC relay supply output provides a maximum current of 0.6 A intended for internal rack relay actuation. Connecting high-draw external inductive loads directly without external suppression diodes can induce reverse EMF transients, tripping the internal short-circuit protection layer.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module support hot-swapping while the rack backplane is energized? A: No. Removing or inserting the power supply module while primary voltage is applied can cause electrical arcing across the backplane connectors, corrupting active bus data transmissions and damaging the solid-state components of adjacent I\/O modules.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Positioning:\u003c\/strong\u003e Always install the power supply module in the dedicated slot on the far left side of the Modicon rack structure to align with the internal hardware power bus pin assignments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Protocols:\u003c\/strong\u003e Connect a low-impedance copper conductor (minimum 2.5 mm square cross-section) from the module protective earth (PE) terminal directly to the central enclosure ground bar to maximize internal surge voltage protection limits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management:\u003c\/strong\u003e Maintain a minimum clearance of 50 mm above and below the module housing to allow unrestricted vertical convection airflow through the IP20 ventilated enclosure, preventing localized heat build-up.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Separation:\u003c\/strong\u003e Route the primary AC input lines through a separate wire duct isolated from low-voltage digital I\/O and communication cables to avoid inductive cross-talk and high-frequency signal degradation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":43449690816602,"sku":"TSXPSY2600M","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/180._4a56ce61-c63e-423e-8991-97f8250c97d9.jpg?v=1780538696","url":"https:\/\/www.spareoil.com\/products\/tsxpsy2600m-schneider-electric-power-supply-module-new-original-stock","provider":"SpareOil Automation","version":"1.0","type":"link"}