{"product_id":"ur-67h-universal-relay-output-card-for-breaker-tripping","title":"UR-67H Universal Relay Output Card for Breaker Tripping","description":"\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin UR-67H (12A0-0006-C6)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-density executive interface for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUniversal Relay (UR)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform. This expansion module provides 8 independent Form-A (Normally Open) relay outputs designed for critical substation operations, including circuit breaker tripping, closing commands, and auxiliary alarm logic. We supply this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your protection system—whether it be a B30, C30, D60, or G60—operates with the high-speed switching and utility-grade reliability required for fault clearance and power system stability.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Multilin\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUR-67H\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrder Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12A0-0006-C6\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Configuration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Form-A (Normally Open) Contacts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContact Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDry Contact\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Switching Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250 VDC \/ 250 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContinuous Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMake and Carry (0.2s)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 A (ANSI\/IEEE C37.90 compliant)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2000 VAC (1 minute)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–40°C to +85°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConfiguration Tool\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEnerVista UR Setup\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChassis Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6U UR Series Chassis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Current Breaker Interfacing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe UR-67H handles a \"Make and Carry\" current of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e30 A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor short durations (0.2 seconds). This allows the module to directly energize heavy-duty circuit breaker trip coils without the need for interposing relays, reducing the total fault clearing time and simplifying cabinet wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectromagnetic Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtility environments generate significant EMI during switching events. This module features a 2000 VAC dielectric strength rating, which isolates field-side transients from the sensitive microprocessor logic. This barrier prevents nuisance trips and hardware damage during severe grid disturbances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtreme Environmental Endurance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineered for the \"Extreme Utility Grade\" standard, the UR-67H operates flawlessly from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e–40°C to +85°C\u003c\/strong\u003e. This thermal resilience permits installation in unconditioned substation kiosks and remote switchgear rooms across diverse geographical climates.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless EnerVista Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module integrates fully with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEnerVista UR Setup\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esoftware. This allows engineers to map outputs to internal logic variables—such as overcurrent elements or bus differential trips—with millisecond-level precision using logic gates and timers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Security:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe plug-in design features robust locking mechanisms for the 6U UR chassis. This ensures that electrical contacts remain intact even in high-vibration substation environments, such as those located near heavy-duty power transformers or reactors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the UR-67H support contact monitoring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the UR-67H (12A0-0006-C6) provides non-monitored dry contacts. If your application requires Trip Circuit Monitoring (TCM) to supervise the continuity of the trip coil, you should consider UR modules with \"M\" or \"S\" designations in the output configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the UR-67H in any UR series relay?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The UR-67H is a universal module compatible with the entire GE Multilin Universal Relay family, including the B30, C30, D30, D60, G30, G60, L30, L60, L90, M60, N60, and T60, provided there is an available I\/O slot in the chassis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the module perform during high-inductive breaking?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe UR-67H features contacts optimized for high-inductive loads. However, for highly inductive DC trip circuits, we recommend using external surge suppression or ensuring the load falls within the module's DC breaking capacity specifications to maximize contact life.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of purchasing a \"Brand New\" module versus refurbished?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProtective relaying is a \"fail-safe\" requirement. Used or refurbished modules may have contact pitting from previous switching events or degraded dielectric barriers. A\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUR-67H ensures the contact resistance is at factory minimums, guaranteeing reliable operation during a genuine power system fault.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42870855106650,"sku":"UR67H","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/89_f0ffeafd-d39a-4a5b-a534-7b778d8e7c0a.jpg?v=1776330308","url":"https:\/\/www.spareoil.com\/products\/ur-67h-universal-relay-output-card-for-breaker-tripping","provider":"SpareOil Automation","version":"1.0","type":"link"}