{"product_id":"ycb301-c100-yokogawa-centum-cs-3000-esb-bus-cable","title":"YCB301-C100 Yokogawa CENTUM CS 3000 ESB Bus Cable","description":"\u003ch2\u003eYokogawa YCB301-C100 ESB Bus Cable\u003c\/h2\u003e\n\u003cp\u003eConfigured for deterministic, low-latency communication in CENTUM VP, CS 3000, and ProSafe-RS control systems, the \u003cstrong\u003eYokogawa YCB301-C100\u003c\/strong\u003e (\u003cstrong\u003eYCB301\u003c\/strong\u003e ESB Bus Cable) provides direct physical execution between Field Control Units (FCUs) and node units.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel \/ Suffix Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription \/ Specification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eYCB301\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eESB Bus Cable (36-pin to 36-pin)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-C100\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCable length: 1 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eYCB301-C100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eLength 1 m (36-pin to 36-pin connectors)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +80 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eShielded ESB Bus Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Material\u003c\/td\u003e\n\u003ctd\u003eHigh-conductivity copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Gauge\u003c\/td\u003e\n\u003ctd\u003e24 AWG typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Material\u003c\/td\u003e\n\u003ctd\u003ePVC, flame-retardant UL 94V-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding\u003c\/td\u003e\n\u003ctd\u003eFoil plus braided shield, \u0026gt;90% coverage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e60 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Impedance\u003c\/td\u003e\n\u003ctd\u003e100 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePropagation Delay\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 5 ns\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 50 pF\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlex Life\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 1,000,000 bending cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP, CENTUM CS 3000, ProSafe-RS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation \u0026amp; Signal Integrity\u003c\/h3\u003e\n\u003cp\u003eThe Yokogawa YCB301-C100 cable relies on high-coverage dual shielding consisting of aluminum foil combined with a tinned copper braid exceeding 90% coverage. This physical arrangement minimizes external electromagnetic interference (EMI) and cross-talk across its 36 conductors during high-speed ESB bus data transmissions. Furthermore, the 100-ohm nominal differential impedance matches the driver and receiver circuits of CENTUM series bus interface modules, maintaining low signal propagation latency under 5 ns\/m and limiting total line capacitance below 50 pF\/m.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What physical latching mechanism prevents intermittent disconnection during operational vibration?\u003c\/p\u003e\n\u003cp\u003eA: The 36-pin connectors at both cable ends integrate heavy-duty mechanical locking latches that physically secure the plug to the interface headers on the Field Control Unit and expansion node chassis.\u003c\/p\u003e\n\u003cp\u003eQ: Is the YCB301-C100 ESB bus cable hot-swappable during active node operation?\u003c\/p\u003e\n\u003cp\u003eA: Disconnecting or connecting the ESB bus cable while the controller and node units are powered disrupts the active hardware communication loop and triggers bus communication fault alarms within the control software. Power to the expansion node sub-rack must be managed per system maintenance protocols prior to cable replacement.\u003c\/p\u003e\n\u003cp\u003eQ: How does the cable construction resist physical wear inside industrial enclosures?\u003c\/p\u003e\n\u003cp\u003eA: The cable assembly utilizes a flame-retardant UL 94V-0 compliant PVC jacket that offers high flex performance exceeding 1,000,000 bending cycles along with industrial-grade oil and abrasion resistance.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEngineers must adhere to standard field installation procedures when routing the YCB301-C100 cable through control cabinets and inter-panel race channels:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eMaintain a minimum bending radius equal to or greater than ten times the overall cable diameter (10x OD) to avoid internal conductor fatigue and shield deformation.\u003c\/li\u003e\n\u003cli\u003eRoute the ESB bus cable inside dedicated low-voltage signal conduits, separated by at least 300 mm from high-voltage AC power lines and motor drive cables to prevent electromagnetic coupling.\u003c\/li\u003e\n\u003cli\u003eVerify that the shield drain wires establish low-impedance ground continuity strictly through the dedicated chassis grounding points on the Yokogawa rack assemblies.\u003c\/li\u003e\n\u003cli\u003eAlign the 36-pin connectors carefully before insertion, push firmly until the side locking clips click into place, and ensure zero strain is applied to the connector neck during cable tie-down.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43901428531290,"sku":"YCB301-С100","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/426.1_5a4bfce2-c585-4e50-a2bc-1e2ce79ad0fe.jpg?v=1787619409","url":"https:\/\/www.spareoil.com\/products\/ycb301-c100-yokogawa-centum-cs-3000-esb-bus-cable","provider":"SpareOil Automation","version":"1.0","type":"link"}