{"product_id":"yokogawa-a1ba4d-05-centum-vp-fio-terminal-board","title":"Yokogawa A1BA4D-05 CENTUM VP FIO Terminal Board","description":"\u003ch2\u003eYokogawa A1BA4D-05 FIO Terminal Board\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa A1BA4D-05\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eA1BA4D\u003c\/strong\u003e Analog Terminal Board, operates as a dedicated hardware component for connecting field analog signals to FIO I\/O modules within CENTUM VP and ProSafe-RS control architectures.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOption \/ Specification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA1BA4D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eTerminal Board for Analog (single and dual-redundant, 16-channel x 1 or 8-channel x 1, DIN rail mount)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-0\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlways 0\u003c\/td\u003e\n\u003ctd\u003eStandard Specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProtection Type\u003c\/td\u003e\n\u003ctd\u003eBasic type with no explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eA1BA4D-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg (Net), 1.5 kg (Shipping)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e26.3 cm x 13.8 cm x 8.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive field terminal interface unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP \/ CS 3000 \/ ProSafe-RS FIO Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Capacity\u003c\/td\u003e\n\u003ctd\u003eSingle and dual-redundant setups (8-channel x 1 or 16-channel x 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Connection\u003c\/td\u003e\n\u003ctd\u003ePressure clamp terminals, KS cable adapter, or MIL connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Modules\u003c\/td\u003e\n\u003ctd\u003eAAI135, AAI835, AAP135, AAI141, AAV141, AAV144, AAB841, AAI841, AAV544, AAI143, AAI543\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V AC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe A1BA4D-05 routing unit consolidates field signal wiring and establishes low-impedance connection paths to FIO analog input and output cards. The pressure clamp terminal block structure maintains stable electrical contact for 4-20 mA HART loop protocol transmitters and control valves, preventing voltage drop errors across high-density marshalling cabinets. Internal signal trace routing supports dual-redundant module pairs to maintain uninterrupted signal continuity without requiring secondary terminal hardware.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the A1BA4D-05 board support dual-redundant I\/O setups?\u003c\/p\u003e\n\u003cp\u003eA: The board features internal bus trace splitting that routes field signals simultaneously to redundant I\/O cables without requiring external jumper terminals.\u003c\/p\u003e\n\u003cp\u003eQ: What method is used to secure field wiring onto the A1BA4D-05 interface?\u003c\/p\u003e\n\u003cp\u003eA: Wires attach directly via integrated pressure clamp screw terminals or connect through pre-assembled KS interface cables and MIL connectors.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eSnap the A1BA4D-05 terminal board onto a standard 35 mm DIN rail inside the marshalling enclosure, verifying that the rail retaining clip engages completely. Strip field conductor insulation to the recommended gauge length before inserting wires into the pressure clamp terminals, tightening screw clamps to the specified torque limit. When interface cables connect to FIO modules via KS or MIL connectors, lock retaining latches to avoid vibration-induced disconnects. Connect the panel ground bus to the terminal board grounding connection to ensure effective signal shield termination.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43838754947162,"sku":"A1BA4D-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/190._d106d8f0-581d-4bd0-a410-53cedfc47518.jpg?v=1786599912","url":"https:\/\/www.spareoil.com\/products\/yokogawa-a1ba4d-05-centum-vp-fio-terminal-board","provider":"SpareOil Automation","version":"1.0","type":"link"}