{"product_id":"yokogawa-aam51-series-analog-output-module","title":"Yokogawa AAM51 Series Analog Output Module","description":"\u003ch2\u003eYokogawa AAM51 Current Voltage Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-precision process signal regulation in CENTUM VP\/CS systems, the \u003cstrong\u003eYokogawa AAM51\u003c\/strong\u003e (\u003cstrong\u003eAAM51\u003c\/strong\u003e Current Voltage Output Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAAM51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 - 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e32.8 x 130 x 107.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e400 mA (5 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Limit\u003c\/td\u003e\n\u003ctd\u003e25.5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e1500 VAC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Process Control \u0026amp; Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe AAM51 module enables multi-channel analog output operations within the Yokogawa control architecture. The device supports standard 4-20 mA DC control loops and ensures signal integrity through robust system-to-field galvanic isolation. Engineers configure output signal ranges and scaling parameters directly via the system software to align with specific field device requirements. The module utilizes an internal 5 VDC power supply to drive its processing logic while maintaining isolation barriers against field-side voltage transients, supporting steady-state performance across complex process networks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: What is the significance of the 1500 VAC withstanding voltage rating?\u003c\/p\u003e\n\u003cp\u003eA: This rating defines the electrical isolation capability between the field wiring and the internal system bus. It ensures that transient voltage spikes on field instruments do not propagate into the backplane, thereby protecting the core processing components from damage.\u003c\/p\u003e\n\u003cp\u003eQ: Are the output signal ranges hardware-selectable?\u003c\/p\u003e\n\u003cp\u003eA: No. The AAM51 utilizes software-based configuration to define output ranges. Operators must utilize the system interface to map specific signal characteristics to the assigned output channels before commissioning the control loop.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Procedure:\u003c\/strong\u003e Align the AAM51 module with the guide rails on the I\/O adapter nest (A2BA3D). Ensure the module seats firmly against the backplane connector to establish proper electrical contact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Shielding:\u003c\/strong\u003e Terminate all cable shields to the cabinet ground bus. Maintain consistent grounding practices to prevent the induction of noise into the analog output signals, which can cause jitter in the control loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management:\u003c\/strong\u003e Install modules with adequate vertical spacing within the cabinet to facilitate convection cooling. Adhere to the ambient operating temperature limits of -10 deg C to +55 deg C to maintain component longevity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop Testing:\u003c\/strong\u003e Prior to placing the module into service, perform a loop test to verify that the software-configured output signal corresponds accurately to the current measured at the field terminal.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43616967622746,"sku":"AAM51","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/481._822b7bf2-84d1-46af-bdb1-ad63d5c7a896.jpg?v=1783490891","url":"https:\/\/www.spareoil.com\/products\/yokogawa-aam51-series-analog-output-module","provider":"SpareOil Automation","version":"1.0","type":"link"}