{"product_id":"yokogawa-ad5-d-analog-i-o-module-centum-vp-cs-3000-new","title":"Yokogawa AD5*D Analog I\/O Module CENTUM VP\/CS 3000 New","description":"\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa AD5*D\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-performance Analog Input\/Output interface within the CENTUM VP and CS 3000 Distributed Control Systems (DCS). This module facilitates the critical exchange of analog signals—such as 4–20 mA current loops and ±10 V DC voltage—between field instruments and the central control logic. We provide this component as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new and original\u003c\/strong\u003e, ensuring maximum signal fidelity and long-term stability for your industrial automation processes.\u003c\/p\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe AD5*D module acts as the primary gateway for process variables, converting real-world analog data into digital values for system processing and translating control commands back into analog outputs for actuators. Its high-resolution A\/D and D\/A conversion circuitry ensures that the DCS receives and sends data with surgical precision. By integrating advanced isolation technology, the AD5*D prevents electrical noise from compromising the system backplane, making it an essential asset for oil refineries, chemical plants, and power generation facilities.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYokogawa Electric Corporation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries Designation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAD5*D\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Input \/ Output Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannel Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTypically 8–16 Channels (Variant Dependent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4–20 mA DC \/ ±10 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConversion Resolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 to 16-bit A\/D or D\/A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Accuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±0.1% of Full Scale\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eChannel-to-channel and System-to-Field\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +60°C (32°F to 140°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.2 cm x 12.5 cm x 13.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.2 kg (Net) \/ 0.5 kg (Shipping)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA \/ Japan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Signal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe AD5*D utilizes dedicated isolation barriers for every channel. This hardware design eliminates ground loop currents and protects the internal DCS logic from high-voltage transients often found in field wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVersatile Signal Handling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module accommodates both current and voltage signals. This flexibility allows engineers to standardize on a single module type for various field devices, including pressure transmitters, flow meters, and control valve positioners.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndustrial environments often face significant temperature fluctuations. The AD5*D maintains a strict ±0.1% accuracy rating across its entire 0°C to +60°C operating range, ensuring consistent process control regardless of cabinet heat buildup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Maintenance Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe slim 3.2 cm profile allows for high-density I\/O configurations in standard 19-inch racks. Technicians can perform maintenance or replacements quickly thanks to the accessible terminal block interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic Response Timing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe high-speed internal bus ensures near-instantaneous signal updates. This speed is vital for safety-critical loops and fast-acting PID control where latency can lead to process instability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between various AD5*D model suffixes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYokogawa uses suffixes to denote specific channel counts, signal types (input vs. output), and hardware revisions. Always check the full part number on your existing module to ensure the replacement AD5*D matches your software configuration and terminal board wiring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix current and voltage signals on the same AD5*D module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn many configurations, the module supports mixed signals depending on the terminal board setup and software parameters. However, you must verify that the specific variant of the AD5*D series you are using supports concurrent multi-signal types.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require external power?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe AD5*D draws its logic power (5 VDC) directly from the station backplane. However, field-side loops (like 4-20mA transmitters) typically require an external 24 VDC power supply, which is often distributed through the associated terminal board.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the AD5*D compatible with both CENTUM VP and CS 3000?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The AD5*D series is a standard I\/O component designed to work seamlessly across both the CENTUM VP and the legacy CS 3000 architectures, providing a reliable migration path or spare parts solution for older systems.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43195051901018,"sku":"AD5*D","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/212._a7c5c419-29d3-4973-80d1-56d3a66a3ac4.jpg?v=1775726957","url":"https:\/\/www.spareoil.com\/products\/yokogawa-ad5-d-analog-i-o-module-centum-vp-cs-3000-new","provider":"SpareOil Automation","version":"1.0","type":"link"}