{"product_id":"yokogawa-adv151-e63-d5a00-32-channel-digital-input-module","title":"Yokogawa ADV151-E63\/D5A00 32 Channel Digital Input Module","description":"\u003ch2\u003eYokogawa ADV151-E63\/D5A00 Digital Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for discrete field signal acquisition in CENTUM VP and CS 3000 control system platforms, the \u003cstrong\u003eYokogawa ADV151-E63\/D5A00\u003c\/strong\u003e (\u003cstrong\u003eADV151\u003c\/strong\u003e Digital Input Module) provides direct physical and electrical execution across 32 isolated 24 VDC channels.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCode Component\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eCode Option\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Definition\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV151\u003c\/td\u003e\n\u003ctd\u003eDigital Input Module (32-channel, 24 VDC, Isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuffix - Type\u003c\/td\u003e\n\u003ctd\u003e-E\u003c\/td\u003e\n\u003ctd\u003eStandard Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuffix - Features\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003eWith status display; with no explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuffix - Protection\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003eWith ISA Standard G3 option and extended temperature (-20 to 70 deg C) option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption Code\u003c\/td\u003e\n\u003ctd\u003e\/D5A00\u003c\/td\u003e\n\u003ctd\u003eDual-redundant power and system interface configuration option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV151-E63\/D5A00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.6 kg Net \/ 2.0 kg Shipping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eCompact module for CENTUM VP I\/O node nest\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e200 mA at 5 VDC, 30 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e32 Digital Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Thresholds\u003c\/td\u003e\n\u003ctd\u003eON state \u0026gt;= 15 VDC, OFF state \u0026lt;= 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e4 to 7 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 VAC withstand between field and system logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 5 ms ON\/OFF switch time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eCE, UL, RoHS, ISA Standard G3 protective coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Interface Features\u003c\/h3\u003e\n\u003cp\u003eThe unit processes discrete 24 VDC contact inputs while utilizing optical isolation to maintain high noise immunity against field transients. Operating across internal system buses, the module incorporates channel-to-channel isolation and 1500 VAC galvanic separation to shield system logic backplanes from field-side electrical interference. Integrated LED indicators display physical channel status in real time to accelerate field loop validation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the ADV151-E63\/D5A00 support hot-swapping during active DCS operations?\u003c\/p\u003e\n\u003cp\u003eA: You can replace the ADV151 module online while the backplane and adjacent I\/O cards remain fully energized. The host Field Control Station maintains system execution and automatically recognizes the replacement module without requiring a full system shutdown.\u003c\/p\u003e\n\u003cp\u003eQ: How does the G3 coating option affect installation environmental limits?\u003c\/p\u003e\n\u003cp\u003eA: The ISA Standard G3 conformal coating allows the module to operate safely in corrosive industrial environments containing airborne moisture and chemical contaminants, extending the operational thermal threshold up to +70 deg C.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Mounting and Earthing:\u003c\/strong\u003e Insert the module firmly into its assigned slot on the CENTUM I\/O node unit until the locking mechanisms click into place. Verify that the node frame earth connection bonds directly to the cabinet protective earth busbar with low-impedance copper conductors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring Terminations:\u003c\/strong\u003e Connect field contact wiring to the matching pressure-clamp terminal block or connector assembly. Dress external wiring away from high-voltage motor feeds to mitigate electromagnetic coupling onto discrete input lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Loop Isolation:\u003c\/strong\u003e Maintain single-point earthing for all incoming cable shields at the cabinet earth bar. Avoid cross-connecting field logic commons across separate isolated banks to preserve the 1500 VAC galvanic boundary between field devices and the DCS control network.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43859787710554,"sku":"ADV151-E63\/D5A00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/172._74bbfda5-accb-4fee-95b2-03b8a76eae2d.jpg?v=1787023681","url":"https:\/\/www.spareoil.com\/products\/yokogawa-adv151-e63-d5a00-32-channel-digital-input-module","provider":"SpareOil Automation","version":"1.0","type":"link"}