{"product_id":"yokogawa-adv151-h50-hart-digital-input-smart-device-dcs","title":"Yokogawa ADV151-H50 HART Digital Input | Smart Device DCS","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ADV151-H50\/D5A00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as an advanced 32-channel digital input interface for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProSafe-RS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDistributed Control Systems. Unlike standard modules, the ADV151-H50 supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHART communication\u003c\/strong\u003e, allowing the DCS to acquire traditional digital status signals while simultaneously extracting diagnostic data from smart field devices. This dual-capability makes it a vital component for modernizing plants that require high-density I\/O alongside deep-level device health monitoring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100% Brand New Original.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown: ADV151 Series\u003c\/h3\u003e\n\u003cp\u003eYokogawa's suffix and option codes define the diagnostic capabilities and physical wiring interface of the ADV151 hardware.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eADV151\u003c\/strong\u003e: Digital Input Module (32-channel, 24 V DC, Isolated).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-H\u003c\/strong\u003e: HART-enabled type for smart device integration and advanced diagnostics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e5\u003c\/strong\u003e: Standard configuration without status display; no explosion protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e0\u003c\/strong\u003e: Basic hardware type.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\/D5A00\u003c\/strong\u003e: Includes KS Cable Interface Adapter [Model: ATD5A-00] for 32-channel digital connectivity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe ADV151-H50\/D5A00 utilizes high-speed logic and robust isolation to protect the system backplane while maintaining 1ms response times.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32 (Individually Isolated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHART Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes (For diagnostics and device integration)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Input Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7 mA per channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt; 1 ms (High-speed capture)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Strength\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eChannel-to-channel and Channel-to-system\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterface Style\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKS Cable Interface Adapter (\/D5A00)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +50°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e130 × 107.5 × 32.8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSmart Device Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe integrated HART support eliminates the need for separate diagnostic hardware. This module passes smart device parameters directly to the control station, allowing operators to monitor sensor health, configuration, and calibration status without leaving the control room.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUltra-Fast Signal Acquisition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA response time of less than 1 ms ensures the system catches every critical state change. This speed proves essential for high-frequency switching applications and safety interlocks where delayed detection could lead to equipment damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Marshaling with KS Cables:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \/D5A00 interface adapter enables the use of pre-fabricated KS cables. This reduces point-to-point manual wiring in the cabinet, significantly lowering commissioning time and virtually eliminating wiring errors during high-density I\/O installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFault Isolation Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRobust channel-to-channel isolation prevents electrical noise or field-side surges from migrating into adjacent loops or the system logic. If a single field contact shorts, the remaining 31 channels continue to function normally, maintaining maximum process availability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the ADV151-H50\/D5A00 support Sequence of Events (SOE) capture?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. While the ADV151-E revision specifically targets SOE, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eADV151-H\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erevision focuses on HART communication and smart device diagnostics. Choose the -H model if you require device health data rather than 1ms time-stamped SOE logs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I connect this module to third-party terminal boards?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The \/D5A00 option provides the KS cable interface, which is the standard Yokogawa connector for interfacing with various terminal boards (such as the AED5D or similar). Always verify that the pinout of your third-party board matches Yokogawa’s KS cable standard.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is it possible to hot-swap this module while the system is running?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. When you configure the ADV151 in a redundant pair on the FIO backplane, you can replace a faulty module without disrupting the 32 input signals, ensuring continuous monitoring of critical safety interlocks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum distance for the KS cable connection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: While specific distances depend on cable gauge and environmental noise, Yokogawa typically recommends keeping KS cable lengths within the standard range specified for the FIO system to maintain high-speed digital signal integrity.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43155487850586,"sku":"ADV151-H50\/D5A00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/175_847c2def-8fdd-4a76-84f2-2bdc14462998.jpg?v=1774928023","url":"https:\/\/www.spareoil.com\/products\/yokogawa-adv151-h50-hart-digital-input-smart-device-dcs","provider":"SpareOil Automation","version":"1.0","type":"link"}