{"product_id":"yokogawa-adv169-p50-centum-vp-64-channel-digital-input-module","title":"Yokogawa ADV169-P50 CENTUM VP 64-Channel Digital Input Module","description":"\u003ch2\u003eYokogawa ADV169-P50 CENTUM VP Digital Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-density signal acquisition in CENTUM VP control systems, the \u003cstrong\u003eYokogawa ADV169-P50\u003c\/strong\u003e (\u003cstrong\u003eADV169\u003c\/strong\u003e Digital Input Module) provides direct physical\/electrical execution across 64 isolated input channels. The hardware processes 24 VDC discrete signals from field switches, proximity sensors, and interlock contacts via ST6 architecture integration. Channel isolation grouped in 16-channel common negative-side banks prevents stray potential differences from disrupting internal backplane logic. The module incorporates Sequence of Events (SOE) timestamp logging capabilities to resolve transient state sequences during automated plant operations.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBase Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eADV169\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eDigital Input Module (64-channel, 24 VDC, ST6-compatible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e-P\u003c\/td\u003e\n\u003ctd\u003eWith status and pushbutton input functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003eBasic type with dual-redundancy support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eAlways 0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV169-P50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e130 x 120 x 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e4.0 W maximum (800 mA at 5 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input (dry contact or DC voltage input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e64 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Isolation\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation per channel bank (2 kV AC withstand)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput ON Voltage\u003c\/td\u003e\n\u003ctd\u003e18 to 26.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput OFF Voltage\u003c\/td\u003e\n\u003ctd\u003e5.0 VDC or lower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Current\u003c\/td\u003e\n\u003ctd\u003e4.1 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e8 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eField Control Unit (FCU) base plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel Isolation \u0026amp; Loop Signal Conditioning\u003c\/h3\u003e\n\u003cp\u003eEngineered for demanding 4-20 mA HART loop protocol plant networks and dense I\/O cabinets, the module features galvanic isolation across every 16-channel common bank to suppress common-mode electrical noise. The internal input circuitry processes status signals with dynamic debounce filtering to eliminate contact bounce errors. By isolating field-side voltage spikes from the internal system bus, the module prevents ground loops from compromising backplane communication integrity across distributed control nodes.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the ADV169-P50 support hot-swapping during live node execution?\u003c\/p\u003e\n\u003cp\u003eA: Technicians can hot-swap the module without powering down the node base plate or interrupting adjacent I\/O cards. However, field power supplies connected via the dedicated KS9 interface cable must remain stable to prevent transient trips on field devices.\u003c\/p\u003e\n\u003cp\u003eQ: How does the channel isolation operate across the 64 inputs?\u003c\/p\u003e\n\u003cp\u003eA: Channels group into four isolated banks of 16 inputs each. Every bank shares a common ground terminal, providing galvanic isolation up to 2 kV AC between separate banks and the backplane logic.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePower down all field-side 24 VDC loops connected to the terminal block before inserting or removing the KS9 signal cable.\u003c\/li\u003e\n\u003cli\u003eAlign the module card guide rails with the designated slot on the Field Control Unit base plate.\u003c\/li\u003e\n\u003cli\u003eSlide the card into the slot until the top and bottom lock levers engage the chassis frame with a mechanical click.\u003c\/li\u003e\n\u003cli\u003eFasten dedicated KS9 cable assemblies securely to the front connector interface, ensuring locking screws are tightened hand-tight.\u003c\/li\u003e\n\u003cli\u003eConnect field cable shielding to the main cabinet grounding bar using a low-impedance grounding clamp. Maintain a single grounding point to avoid ground loops.\u003c\/li\u003e\n\u003cli\u003eVerify that high-voltage AC cables maintain a minimum clearance distance of 200 mm from the digital input field wiring harness.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43865935839322,"sku":"ADV169-P50","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/362._6284d3e7-7e00-41a5-b074-8fee0708bd34.jpg?v=1787101874","url":"https:\/\/www.spareoil.com\/products\/yokogawa-adv169-p50-centum-vp-64-channel-digital-input-module","provider":"SpareOil Automation","version":"1.0","type":"link"}