{"product_id":"yokogawa-amm22-s3-centum-vp-16-channel-analog-input-fio-card","title":"Yokogawa AMM22-S3 CENTUM VP 16-Channel Analog Input FIO Card","description":"\u003ch2\u003eYokogawa AMM22-S3 CENTUM VP Series Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-resolution signal acquisition and multiplexing in CENTUM VP and CS 3000 systems, the \u003cstrong\u003eYokogawa AMM22-S3\u003c\/strong\u003e (\u003cstrong\u003eAMM22\u003c\/strong\u003e Analog Input Module) provides direct physical\/electrical execution. This hardware component interfaces 16 field-side analog process loops with the core network subsystem via internal multiplexing circuits, processing standard current and voltage inputs without requiring external isolation barriers or auxiliary conversion modules.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAMM22-S3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e2.5 cm x 12.7 cm x 20.3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e200 mA at 5 VDC; 150 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e16 Isolated Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eplus\/minus 0.1 percent of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 VAC (field to backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; DCS Instrumentation Features\u003c\/h3\u003e\n\u003cp\u003eThe module integrates a dedicated 4-20 mA HART loop protocol layer enabling seamless pass-through communication between field instruments and the CENTUM VP engineering workstation. Internal measurement nodes feature individual channel-to-channel isolation parameters to mitigate ground loop currents and prevent common-mode voltage differentials from corrupting adjacent channels. For thermal safety and accuracy across varying installation conditions, electronic temperature sensors provide automated cold junction compensation (CJC) calculation routines when processing external thermocouple signals via matching terminal boards, ensuring deterministic A\/D converter scaling.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the AMM22-S3 support hot-swapping during active system operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports hot-swapping when utilized within a compliant FIO nest; however, ensure the backplane power is stable and the I\/O bus communication is verified before extraction to prevent transient signal disruption.\u003c\/p\u003e\n\u003cp\u003eQ: How should the input impedance be addressed when switching between voltage and current modes?\u003c\/p\u003e\n\u003cp\u003eA: The module maintains an internal 250 ohm impedance specifically for 4-20 mA current loops. When reconfiguring to voltage mode (1-5 VDC or 0-10 VDC), verify that the external loop configuration aligns with the terminal impedance requirements to prevent signal attenuation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the module is seated firmly into the designated FIO nest slot. The locking mechanism must engage fully to establish a reliable connection with the backplane bus.\u003c\/li\u003e\n\u003cli\u003eVerify that the field wiring terminal board is securely fastened to the module front interface. Use shielded twisted-pair cabling for all analog inputs to maintain the specified electromagnetic compatibility.\u003c\/li\u003e\n\u003cli\u003eGround the cable shields at the designated common ground bar within the cabinet to minimize noise induction. Do not terminate shields at the module terminals unless specifically required by the site control loop drawing.\u003c\/li\u003e\n\u003cli\u003eAfter power-up, observe the status LEDs. A solid green indicator confirms hardware initialization and successful communication with the field control station.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":42870830760026,"sku":"AMM22","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/130.1_79e4d515-e48c-4cb1-89fd-247de3d60135.jpg?v=1772587536","url":"https:\/\/www.spareoil.com\/products\/yokogawa-amm22-s3-centum-vp-16-channel-analog-input-fio-card","provider":"SpareOil Automation","version":"1.0","type":"link"}