{"product_id":"yokogawa-asd533-s00-centum-cs-fio-digital-output-module","title":"Yokogawa ASD533-S00 Centum CS FIO Digital Output Module","description":"\u003ch2\u003eYokogawa ASD533-S00 Centum VP Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa ASD533-S00\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eASD533\u003c\/strong\u003e Digital Output Module, operates as a dedicated hardware component for discrete control signal execution within Centum CS \/ Centum VP platforms.\u003c\/p\u003e\n\u003ch3\u003eLayout Configuration Selection: Layout 1\u003c\/h3\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eASD533-S00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.3 cm x 13.5 cm x 14.7 cm (1.3 in x 5.3 in x 5.8 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDetermined by connected I\/O loading thresholds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Output Channels\u003c\/td\u003e\n\u003ctd\u003e32 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage Range\u003c\/td\u003e\n\u003ctd\u003e19.2 to 28.8 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Current\u003c\/td\u003e\n\u003ctd\u003e100 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e10 ms or less per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e1500 VDC (Channel-to-channel and channel-to-system)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Circuits\u003c\/td\u003e\n\u003ctd\u003eOvercurrent, short-circuit, surge suppression\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e5 to 95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; DCS Instrumentation Technical Attributes\u003c\/h3\u003e\n\u003cp\u003eThis Field I\/O (FIO) subsystem component delivers stable ON\/OFF signals to solenoids, relays, and indicator lamps via an isolated solid-state circuit matrix. The module features channel-to-channel and channel-to-system galvanic isolation barriers rated up to 1500 VDC, preventing field-side voltage transients from disrupting internal system bus communications. Additionally, integrated diagnostic electronics perform continuous self-test routines and drive status LED indicators, while the internal architecture maintains high noise immunity against electromagnetic interference in dense control panels.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does this specific module configuration support direct installation in hazardous areas?\u003c\/p\u003e\n\u003cp\u003eA: No. The S00 suffix designates the general-purpose, non-explosion-proof variant. For execution inside intrinsically safe environments, you must deploy the specialized SD3S0 variant or implement external isolation barriers.\u003c\/p\u003e\n\u003cp\u003eQ: How does the hardware respond during short-circuit or overcurrent conditions on a field loop?\u003c\/p\u003e\n\u003cp\u003eA: The module activates internal overcurrent and short-circuit protection circuits to isolate the faulted channel immediately, preserving the operating integrity of the remaining channels and preventing thermal damage.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Placement:\u003c\/strong\u003e Slot the hardware directly into the designated FIO node rack position, ensuring the rear multi-pin connector interfaces cleanly with the active system backplane before securing the assembly fasteners.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Configurations:\u003c\/strong\u003e Route all 24 VDC discrete field load lines through separate wiring tracks, ensuring high-current power lines do not run parallel to low-voltage network cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e Attach all external field instrument cable shields to a single-point cabinet ground bus bar to eliminate ground loops and minimize electrical noise pickup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Conditions:\u003c\/strong\u003e Mount the module vertically to allow correct convective airflow through the housing slots, keeping ambient temperatures inside the cabinet between -20 and +70 deg C.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43681010614362,"sku":"ASD533-S00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/594..jpg?v=1784511227","url":"https:\/\/www.spareoil.com\/products\/yokogawa-asd533-s00-centum-cs-fio-digital-output-module","provider":"SpareOil Automation","version":"1.0","type":"link"}