{"product_id":"yokogawa-asi533-s00-s1-centum-vp-analog-input-module-32-channel","title":"Yokogawa ASI533-S00 S1 CENTUM VP Analog Input Module 32 Channel","description":"\u003ch2\u003eYokogawa ASI533-S00 S1 CENTUM VP Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa ASI533-S00 S1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eASI533\u003c\/strong\u003e Analog Input Module, operates as a dedicated hardware component for high-density analog signal acquisition within Yokogawa CENTUM VP platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOption\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eASI533\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eHigh-density 32-channel analog input module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-S00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard Variant\u003c\/td\u003e\n\u003ctd\u003eStandard functional hardware specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eS1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOption Code\u003c\/td\u003e\n\u003ctd\u003eSingle\/standard terminal interface design style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eASI533-S00 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg to 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e150 mm x 25 mm x 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 W maximum (supplied via system backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eYokogawa CENTUM VP DCS platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Density\u003c\/td\u003e\n\u003ctd\u003e32 isolated analog input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Signal Ranges\u003c\/td\u003e\n\u003ctd\u003e+\/-10 V DC, 4-20 mA DC, thermocouple ranges\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Conversion\u003c\/td\u003e\n\u003ctd\u003e16-bit A\/D conversion resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScan Cycle\u003c\/td\u003e\n\u003ctd\u003eConfigurable, typically 100 ms per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalvanic Isolation\u003c\/td\u003e\n\u003ctd\u003eChannel-to-channel and channel-to-system isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Format\u003c\/td\u003e\n\u003ctd\u003eField Control Station (FCS) cabinet rack slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe ASI533-S00 S1 input module routes 32 discrete instrument channels through independent galvanic isolation barriers to protect backplane processing logic from field line surges. Standard 4-20 mA HART loop protocol signals and DC voltage measurements undergo 16-bit analog-to-digital conversion before transmission to the Field Control Station CPU. Integrated cold junction compensation (CJC) algorithms stabilize thermocouple measurement channels against ambient enclosure drift, while onboard continuous self-test diagnostics verify loop continuity and signal health.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the high-density 32-channel architecture maintain channel isolation during field grounding faults?\u003c\/p\u003e\n\u003cp\u003eA: Each channel incorporates individual galvanic isolation components that isolate signal returns up to system breakdown limits. This prevents ground potential variations on one field circuit from inducing measurement offsets on adjacent channels.\u003c\/p\u003e\n\u003cp\u003eQ: Can the ASI533-S00 S1 module be installed into an active rack node without shutting down the FCS system?\u003c\/p\u003e\n\u003cp\u003eA: The module supports rack slot seating under backplane power, provided field technicians engage the module retention screws completely and adhere to station hot-swap procedures to avoid transient system alarms.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eSlide the ASI533-S00 S1 module into its assigned slot in the CENTUM VP FCS rack. Push the assembly inward until the backplane edge connector seats fully, then tighten top and bottom panel screws to secure the chassis against vibration.\u003c\/p\u003e\n\u003cp\u003eConnect incoming field signals using shielded twisted-pair cabling. Terminate drain wires at the main cabinet shield bus using short wire runs to maintain low RF impedance. Route 4-20 mA current cables away from high-voltage AC lines to minimize electromagnetic interference across sensitive measurement loops.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43823052161114,"sku":"ASI533-S00 S1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/788.jpg?v=1786413560","url":"https:\/\/www.spareoil.com\/products\/yokogawa-asi533-s00-s1-centum-vp-analog-input-module-32-channel","provider":"SpareOil Automation","version":"1.0","type":"link"}