{"product_id":"yokogawa-centum-vp-cs-3000-pw482-11-system-power-supply-module","title":"Yokogawa CENTUM VP\/CS 3000 PW482-11 System Power Supply Module","description":"\u003ch2\u003eYOKOGAWA PW482-11 Power Supply Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-availability power distribution in CENTUM VP and CENTUM CS 3000 network platforms, the \u003cstrong\u003eYOKOGAWA PW482-11\u003c\/strong\u003e (\u003cstrong\u003ePW482-11\u003c\/strong\u003e Power Supply Unit) provides direct physical and electrical execution of regulated 24 VDC power delivery.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePW482-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.75 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e25.4 x 2.5 x 20.3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC Nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e5.0 A Continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Connectivity and Isolation\u003c\/h3\u003e\n\u003cp\u003eThe module manages power regulation within the Field Control Station (FCS), interfacing directly with the backplane to supply consistent voltage to processors and I\/O modules. To ensure system uptime, the hardware supports 1:1 dual-redundant configurations, enabling load sharing and bumpless failover if input voltage is lost or an internal fault is detected. Integrated protection circuits provide defense against overvoltage, overcurrent, and thermal-induced shutdown. Galvanic isolation between the wide-range AC input and the DC output stage prevents line-side transients from affecting sensitive control circuitry, maintaining deterministic performance in complex industrial electrical environments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Is the PW482-11 compatible with legacy PW482-10 mounting arrangements?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the PW482-11 is designed as a direct functional replacement for the legacy PW482-10, offering improved component longevity and thermal management while maintaining identical form-factor compatibility for existing FIO baseplates.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module support hot-swapping in a redundant pair?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports hot-replacement when deployed in a 1:1 redundant setup. Ensure that the diagnostic LEDs indicate the standby unit is ready to assume the full load before extracting the primary module to ensure continuous operation of the system bus.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the power supply rack to the cabinet frame. Align the PW482-11 with the baseplate guide rails and insert the unit until the rear backplane connectors are fully seated. Secure the locking mechanism to ensure structural stability under operational vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Wiring:\u003c\/strong\u003e Connect the 100–240 VAC supply to the module terminals. Ensure an upstream circuit breaker or fuse is installed to provide adequate protection against line-side faults. Use shielded power cables if required to adhere to specific electromagnetic compatibility standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management:\u003c\/strong\u003e The PW482-11 utilizes natural convection for cooling. Maintain at least 5 cm of clear space above and below the module to facilitate airflow. Do not install heat-generating components directly beneath the unit to prevent localized temperature increases that may trigger thermal protection.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":42870875357274,"sku":"PW482-11","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/105._70de05f6-2efa-4252-aab2-0c731bdfc15e.jpg?v=1772071077","url":"https:\/\/www.spareoil.com\/products\/yokogawa-centum-vp-cs-3000-pw482-11-system-power-supply-module","provider":"SpareOil Automation","version":"1.0","type":"link"}