{"product_id":"yokogawa-f3cu04-0s-z01-fa-m3-4-loop-pid-module","title":"Yokogawa F3CU04-0S\/Z01 FA-M3 4-Loop PID Module","description":"\u003ch2\u003eYokogawa F3CU04-0S\/Z01 FA-M3 Temperature Control and PID Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for 4-loop temperature regulation and independent loop processing in FA-M3 platforms, the \u003cstrong\u003eYokogawa F3CU04-0S\/Z01 S1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eF3CU04-0S\/Z01\u003c\/strong\u003e Temperature Control and PID Module, provides direct physical\/electrical execution. The hardware offloads complex PID computations from the main CPU, executing high-speed input conversion with 0.1 percent full-scale accuracy across universal analog field inputs.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eF3CU04-0S\/Z01 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJAPAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.20 kg (Shipping Weight: 2.0 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e28.9 mm x 100 mm x 106.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e460 mA at 5 VDC (Backplane), 24 VDC external (max 200 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Loops\u003c\/td\u003e\n\u003ctd\u003e4 independent PID loops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Period\u003c\/td\u003e\n\u003ctd\u003e200 ms for 4 loops, 100 ms for 2 loops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 percent of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Types\u003c\/td\u003e\n\u003ctd\u003eThermocouple (15 types), RTD (9 types), DC voltage\/current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003ePhotocoupler and transformer isolation (1500 VAC for 1 min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Connection\u003c\/td\u003e\n\u003ctd\u003e18-point terminal block with M3.5 screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe F3CU04-0S\/Z01 features channel-to-channel isolation and galvanic transformer barriers rated for 1500 VAC to isolate process sensor loops from system backplane logic. The module processes universal thermocouple, RTD, and 4-20 mA HART loop protocol analog inputs, applying dynamic auto-tuning and fuzzy logic overshoot suppression. Integrated CJC (cold junction compensation) circuits adjust for thermal gradients at the terminal block to maintain primary measurement precision.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the primary backplane current draw for the F3CU04-0S\/Z01 PID module?\u003c\/p\u003e\n\u003cp\u003eA: The module draws 460 mA from the internal 5 VDC FA-M3 backplane bus, with external loop field power requiring up to 200 mA at 24 VDC.\u003c\/p\u003e\n\u003cp\u003eQ: Can the 18-point terminal block be removed without disconnecting individual loop wires?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the M3.5 screw terminal block is detachable, allowing rapid module swap-outs while preserving existing field wiring terminations.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the F3CU04-0S\/Z01 into an available slot on the FA-M3 base unit and lock the top connector latch firmly in place. Tighten the 18-point terminal block M3.5 screws to a torque spec of 0.8 N-m to prevent high-resistance connections under plant vibration conditions.\u003c\/p\u003e\n\u003cp\u003eRoute thermocouple, RTD, and analog signal wiring inside shielded twisted-pair cables separate from high-voltage AC lines. Ground the cable shield at a single cabinet earth point to prevent ground loops. Allow a warm-up period of at least 30 minutes after initial energization to achieve thermal equilibrium for accurate cold junction compensation.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43831810162778,"sku":"F3CU04-0S\/Z01 S1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/3_418eefc7-0c7d-44df-8fbe-37245ec47ac5.jpg?v=1786497348","url":"https:\/\/www.spareoil.com\/products\/yokogawa-f3cu04-0s-z01-fa-m3-4-loop-pid-module","provider":"SpareOil Automation","version":"1.0","type":"link"}